Early Functional Outcome of Ceramic on Ceramic Total Hip Replacement Using a 36 mm Diameter Femoral Head

Journal Title: Journal of Medical Science And clinical Research - Year 2018, Vol 6, Issue 4

Abstract

head using a ceramic on ceramic bearing at a tertiary care hospital. Patients aged 30 years and above were included in the study with the oldest patient being 75 years. The most common indication for surgery was secondary osteoarthritis of the hip joint due to avascular necrosis of the femur head (21 patients). Other causes were primary osteoarthritis of the hip(3 patients),intermediate stage of avascular necrosis of femur head which had not progressed to the stage of osteoarthritis (2 patients), osteoarthritis post old history of trauma(2 patients) , osteoarthritis post healed tuberculosis of the hip(1 patient), and ankylosing spondylitis (1 patient) . A thorough clinical and radiological examination was performed. All the patients were advised to do isometric quadriceps exercise 8 hours after surgery. Patients were made to sit up on 1st post-operative day and adviced knee bending exercises. Patients were made to stand up and walk on 1stpost-operative day non weight bearing or partial weight bearing as tolerated. Sutures were removed on 12th post operativeday. Average duration of stayin hospital was 5 days. The duration of follow up was till 18 months. Patients were assessed by the modified Harris Hip Score and WOMAC score after 12 and 18 months post op. All the patients were followed up regularly, no patients were lost for follow up.There was no complication during the period of study. The mean Modified Harris Hip Score increased significantly from 26.6 pre operatively to 89.3 post operatively at 12 months and 90.0 at 18 months. The mean WOMAC score has decreased significantly from 70.5 pre operatively to 14.8 post operatively at 12 months and 14.2 at 18 months. This proves that uncemented total hip arthroplasty done with a 36 mm femur head and a ceramic on ceramic bearing gives excellent results.

Authors and Affiliations

Dr Sonu Mehta

Keywords

Related Articles

Flowcytometric Immunophenotyping Study of Acute Lymphoblastic Leukemia at M.Y. Hospital Indore

Background: ALL accounts for 12% of all leukemia (but 80% in children). Global incidence is about 3 per 100,000 population, in which 3 out of 4 cases occurring under 6 years age. T-cell acute lymphoblastic leukemia (T-AL...

Significance of Inter-Ictal Period in Detection of Epilepsy by EEG

Objectives: To evaluate the sensitivity of EEG in diagnosing Epilepsy in different inter-ictal periods. Materials and Methods: The study was done from June 2014 to May 2015.One hundred and thirteen clinically diagnosed c...

Gliosarcomas: Are They Still Dreadful?

Introduction: Gliosarcomas are highly malignant tumours of the central nervous system, having the worst prognosis. Gliosarcomas have the same epidemiology and natural history like Glioblastoma whereas the incidence is mo...

A Study on Precipitating Factors in Pemphigus

Background: Pemphigus is the most common cause of morbidity and mortality among dermatological diseases even after treatment with immunosuppressants. There are not many studies on precipitating factors of pemphigus from...

A Rare Case of Carcinoma Oesophagus in 16 Year Old Male Patient Nutritional Deficiency

Esophageal carcinoma is commonly seen in elderly. Most common etiological factors are environment related with constant long term exposure of carcinogens. Hence, it is rarely seen in younger age groups (<18 years).Till d...

Download PDF file
  • EP ID EP512788
  • DOI -
  • Views 67
  • Downloads 0

How To Cite

Dr Sonu Mehta (2018). Early Functional Outcome of Ceramic on Ceramic Total Hip Replacement Using a 36 mm Diameter Femoral Head. Journal of Medical Science And clinical Research, 6(4), 1020-1028. https://europub.co.uk/articles/-A-512788