Effect of construction orientation on the microstructure and properties of SLM Ti alloy clasps
Journal Title: 口腔疾病防治 - Year 2019, Vol 27, Issue 1
Abstract
Objective To investigate the physical properties of Ti-6Al-4V clasps generated by selective laser melting (SLM) with different construction directions and to compare these clasps with cast clasps, which could provide a basis for fabricating SLM clasps with high precision and excellent mechanical properties. Methods Ti-6Al-4V clasps were fabricated by SLM at 0 degrees (SLM0 group), 45 degrees (SLM45 group) and 90 degrees (SLM90 group) (n = 12). Twelve clasps were cast by the casting method as the control group. Meanwhile, four metal abutments were cast randomly as the abutments of the four groups. X-ray was used to detect cracks in the clasps of each group. The roughness of the clasps was measured by confocal microscopy, the fitness tests between clasps and abutment were processed by stereomicroscopy, and the microstructure of clasps in each group was observed under a metallographic microscope to evaluate the physical properties. Results There were 0-8 visible cracks in the casting group but no obvious defects in the SLM groups. The maximum surface roughness was observed in the cast group (18.102 ± 3.762) μm, while the minimum roughness was observed in the SLM90 group (5.942 ± 1.486) μm (P < 0.05). There was no statistically significant difference in surface roughness between the SLM0 group [(8.711 ± 2.378) μm] and the SLM45 group [(8.513 ± 1.161) μm]. Fitness was worst in the casting group [(68.445 ± 14.876) μm] and best in the SLM90 group [(33.417 ± 5.880) μm] (P < 0.05). There was no statistically significant difference in fitness between the SLM0 group [(52.917 ± 12.102) μm] and the SLM45 group [(50.889 ± 7.011) μm]. In addition, the growth direction of the β grains was roughly parallel to the build direction, and acicular α grains were present between β grains. SLM was composed of fine grains, while the cast group had large grains. Conclusions Specimens generated by SLM had finer grains than cast specimens. In addition, SLM90 clasps had the highest fitness and the lowest surface roughness.
Authors and Affiliations
XIE Wenqiang, WANG Jieqi, ZHUANG Peilin, LI Xiaoyu, ZHENG Meihua, ZHANG Wen, WEI Peiling
Application of digital implant guide plate in oral implant restoration
Digital implant guides have enabled "repair-oriented" implant restoration to become a reality by allowing an implant to be designed for an ideal site, maximizing the use of existing alveolar bone, and increasing the pred...
Application of extended clavicular epithelial flap in postoperative defect repair in elderly patients with oral cancer
Objective To explore the clinical application of an extended clavicular epithelial flap with a transverse cervical arterial blood supply in the repair of postoperative soft tissue defects in elderly patients with oral ca...
A comparison of the effect of different nickel-titanium instruments combined with ultrasonic irrigation on root canal preparation
Objective To compare the removal efficiency and the amounts of apically extruded debris using Twisted File (TF), Twisted File Adaptive (TFA), ProTaper, and ProTaper Next combined with ultrasonic irrigation and to provide...
Evaluation of resin inlay restoration after root canal therapy for deciduous molars
Objective To explore the clinical effect of composite resin inlays in repairing large areas of primary molar defects after root canal treatment to provide a reference for the restoration of carious primary molars.Methods...
Advances in adenoid hypertrophy and dental and maxillofacial deformities
Adenoid hypertrophy may cause abnormal breathing habits in children, which may cause abnormal development of soft and hard tissues of the maxillofacial region. Hypertrophic adenoids can cause the mandible to rotate backw...