Abstract

Background: Drilling of bone is used to fix the fractures with screws, wires or plates. The interaction between hole surface surface and fracture stabilization components is effective in the bonding strength of the stabilization process. During bone drilling, the temperature could increase above 47 °C and cause irreversible thermal necrosis. The surface roughness can be considered as a sign of damage of the bone cells. Methods: This study looks at the effect of rotational speed of drilling of bone on production of surface defects to determine the best processing condition for minimizing the osteonecrosis and surface defects. Seven different rotational speeds in drilling beef femur were used-in non-cooling and liquid cooling phases. In all tests the temperature was measured. After cutting samples, using hematoxylin-eosin staining were stained for detection of surface defects. Results: The lowest heat prodution was with use of liquid cooling. The drill speed of 1500 rpm with liquid cooling showed the maximum temperature of 48.5°C without production of surface debris and defects as witnessed in stained bone segment. Conclusions: Cooling application in bone drilling process avoids over and thus less thermal necrosis, which gives the lowest number of surface defects and highest quality wall surface hole.

Authors and Affiliations

Ehsan Shakouri, Fatemeh Zareh, Ahmad Majd, Hossein Haghigh Hassanali

Keywords

Related Articles

Evaluation of Nutrient Foramen of the Femur, Tibia, and Fibula Bones in Center of Iran

Background: Nutritional arteries are the main source of blood supply to long bones. These foramina enable the blood vessels and nerves to pass through the cortex of the bone. The exact location and distribution of nutrie...

Elderly Femoral Neck Fracture: Hemiarthroplasty via Direct Anterior Approach Surgical Techniques and Literature Review

Introduction: Nowadays, there is consensus regarding arthroplasty as the preferred treatment method for displaced femoral neck fracture among the elderly population. Although posterior and lateral surgical approaches are...

A Review of Osteoarthritis Model Construction Techniques

Osteoarthritis (OA) can affect any joint in body. Post-traumatic osteoarthritis (PTOA) often occurs due to knee joint injuries and damage to joint stabilization structures, such as anterior cruciate ligament (ACL) and/or...

Evaluation of complication rate of insertion of bridging External fixator in periarticular comminuted fracture of knee and ankle

Background: The open fracture of femur and leg is one of the most common fracture of orthopedic injuries. Utilization of external fixator has worldward acceptance. Pin tract infection, neurovascular injuries, compartment...

Surgical Fixation of Distal Periprosthetic Humerus Fractures using a Distal Femoral Locking Plate: Surgical Technique and Report of Three Cases

Periprosthetic fractures about the humerus are a rare but difficult complication of shoulder arthroplasty, occurring in up to 3% of cases. Depending on the fracture pattern, open reduction and internal fixation (ORIF) ma...