Effect of Twisted Tape Insert on Heat Transfer Enhancement in Counter Flow Co Axial Double Pipe Heat Exchanger using CFD
Journal Title: International Journal of Trend in Scientific Research and Development - Year 2020, Vol 4, Issue 5
Abstract
The twisted tape has great potential as a device for enhancing heat transfer. Twisted tapes hold the advantage over other techniques as they ease of installation and operation. From the previous studies, it is also found that there were rare researches on a combination of twisted tape insert and nanofluids. Therefore, the scope of the present study is concerned with the enhancement of the double pipe heat exchanger performance through twisted tape insert. To achieve these aims, a numerical model was constructed in order to investigate the effect of twisted tape on the heat transfer coefficient. This study investigates the heat transfer characteristics of Counter flow co axial double pipe heat exchanger using Al2O3 water nanofluids by inserting twisted tape turbulator of pitch 25mm inside the inner tube. The Al2O3 water nanofluids 0.4 1.6 particle volume concentrations were used. The simulation were conducted under the turbulent flow in the Reynold’s number range of 4000 Re 20000. It is found that from the computational outcomes, the heat exchanger with twisted tape insert unveiled the best Nusselt number of 487.24 at Re=20,000 at 1.6 vol. of nanoparticle. By comparison, the Nusselt number of double pipe heat exchanger with twisted tape insert is 8.27 higher than with wire coil insert. Prof. Arvind Singh | Piyush Pathak "Effect of Twisted Tape Insert on Heat Transfer Enhancement in Counter Flow Co-Axial Double Pipe Heat Exchanger using CFD" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-4 | Issue-5 , August 2020, URL: https://www.ijtsrd.com/papers/ijtsrd33047.pdf Paper Url :https://www.ijtsrd.com/engineering/mechanical-engineering/33047/effect-of-twisted-tape-insert-on-heat-transfer-enhancement-in-counter-flow-coaxial-double-pipe-heat-exchanger-using-cfd/prof-arvind-singh
Authors and Affiliations
Prof. Arvind Singh | Piyush Pathak
Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter
In this paper, a shunt active power filter (SAPF) based on adaptive hysteresis band current controller (HBCC) is proposed for limiting the harmonics in load current and also compensate the reactive power for 3 phase non-...
Problems Faced by Women in Agriculture and Its Allied Fields
Though the constitution of India has provided equal rights and privileges to men and women, womens lives are shaped by social customs that blind their approach. Thus there rises the need to bring women into the mainstrea...
CFD Analysis of Solar Air Heater for Enhancenment of Heat Transfer Through Inclined Rib Roughness
A 3-dimensional CFD analysis has been carried out of solar air heater to study heat transfer and fluid flow behavior in a rectangular duct of a solar air heater with one roughened wall having combination of circular and...
A Proposed Fuzzy Inventory Management Policy
Managing inventory under inaccurate or incomplete data considers a complex process to find the optimal policy to reduce total inventory costs. Hence, we resort in this paper to the use of the fuzzy technique to treat thi...
A Review of Asthi Bhagna and Bhagna Chikitsa in Ayurveda
Ayurveda is the most ancient practiced medical science. The human body Sharira is described as a combination of external factors the Atma soul , Manas mind and Pancha Maha Bhoota. The most important supportive framework...