Abstract

Objective To investigate the inactivation function of 25Gy X-ray irradiation on apheresis platelets’ lymphocytes and its effect on the quantity of apheresis platelets(AP). Methods Twenty healthy voluntary AP donors from January to May 2021 in our center were selected, and 2 bags of AP were donated by each of them. The APs were divided into two groups to undergo X-ray and γ-ray irradiation for 10 min. Lymphocytes were separated from AP samples, before and after irradiation, by lymphocyte separation solution to analyze and compare the effect of X-ray and γ-ray on lymphocyte proliferation. The CD41b, CD62p, blood routine and pH of APs before and 1-day/3-day after irradiation were detected. SPSS statistical software was used to analyze and compare the differences between groups by independent sample t-test. Results After 25Gy X-ray and γ-ray irradiation, the inhibition rates of lymphocytes were (98.034±1.778)% and (97.882±1.915)%, respectively.Compared with the γ irradiation group, the difference of Plt, PDW, MPV, P-LCR, PCT, pH, CD41b and CD62p between 1-day and 3-day group after 25Gy X-ray irradiation showed not statistically significance (P>0.05). Conclusion 25Gy X-ray irradiation can effectively inactivate lymphocytes in APs, and the radiation effect was equivalent with γ-ray; at the same time, there was no significant influence on the quantity of APs.

Authors and Affiliations

Chen CHENG, Yijing CHEN, Yi ZHANG, Hailong ZHUO, Qun LUO

Keywords

Related Articles

Prediction model of platelet transfusion refractoriness in patients with hematological disorders

Objective To explore the risk factors for platelet transfusion refractoriness(PTR)in patients with hematological disorders, construct a prediction model and validate the model efficacy. Methods Patients with hematologica...

Molecular analysis of the new allele 803delC of subtype B

Objective To analyze the serological characteristics and molecular mechanism of a novel B subtype allele 803delC. Methods ABO blood group was detected by serological method. Sequence-specific primer polymerase chain reac...

Expert consensus on technical specifications for ABO blood group detection in clinical laboratories in Shenzhen

To meet the time-sensitive requirements of transfusion therapy, clinical laboratory testing for ABO blood typing must be conducted swiftly and accurately. To achieve this, laboratory technicians need to master the underl...

Determination of tromethamine residues in human coagulation factor Ⅷ by high performance liquid chromatography method

Objective To develop and verify high performance liquid chromatography (HPLC) detection for tromethamine (Tris) residues in human coagulation factor Ⅷ. Methods Alanine was used as internal standard, and AQC for pre-colum...

Effect of storage time on the chemokine storage and chemokine scavenging function of erythrocyte atypical chemokine receptor 1

Objective To determine the effect of storage time on the chemokine storage and chemokine scavenging function of erythrocyte atypical chemokine receptor 1(ACKR1). Methods Samples from six bags of red blood cells product,...

Download PDF file
  • EP ID EP738317
  • DOI 10.13303/j.cjbt.issn.1004-549x.2022.08.010
  • Views 74
  • Downloads 0

How To Cite

Chen CHENG, Yijing CHEN, Yi ZHANG, Hailong ZHUO, Qun LUO (2022). Effect of X-ray irradiation on the inactivation of lymphocytes and the quality of apheresis platelets. Chinese Journal of Blood Transfusion, 35(8), -. https://europub.co.uk/articles/-A-738317