Effectiveness of an electronic apex locator used after preflaring of cervical and middle third

Journal Title: RSBO - Year 2012, Vol 9, Issue 2

Abstract

Introduction: The electronic method has been studied and improved aiming to add precision, speed and reliability of the measurement technique to determine the exact location of the working length. Currently, the root canal preparation recommends prior to determine the tooth length and consequent perform instrumentation of the apical portion, a previous preflaring of the cervical and middle thirds in various techniques. This procedure may provide a reduction in system impedance, leading to read errors by the apex locators. Objective: Investigate the influence of preflaring of the cervical and middle thirds on the accuracy of measuring the working length by apex locators. Material and methods: Twenty-five mesial roots of molars were used and had their crowns cut at the cemento-enamel junction. The actual measure of each root canal was performed and then the samples were embedded into a mixture of alginate, used as a conducting medium, where electronic measurements were taken with apex locator before and after preflaring of the canals with Gates-Glidden drills in descending order (#4, #3, #2). Measurements obtained by electronic method were then compared with the actual measurement of the root canal. The results were tabulated and submitted to the Student t test Results: The results show that there was no statistical significance (p<0.05) between the readings before and after preflaring. Readings closer to the foraminal ending occurred in the group after preflaring with Gates Glidden. Conclusion: It was concluded that preflaring with Gates Glidden drills were not able to influence significantly the accuracy of apex locator in determining the exact working length.

Authors and Affiliations

João Marcelo Teixeira, Myrna Barcellos, Marco André Pinho, Carlos Augusto Barbosa, Rivail Fidel, Sandra Fide

Keywords

Related Articles

 In vivo evaluation of tissue response to new endodontic sealers

 Introduction: The sealers can be in direct contact with the periapical tissues. Thus, these materials must have appropriate physical and biological properties, providing conditions for repair to occur. Objective: T...

In vitro analysis of the apical deformation, using a different number of files during the instrumentation

Introduction and objective: The aim of the present study was to evaluate in vitro the apical deformation in roots of crooked lower incisors with mesio-distal flattening, using a different number of files during the instr...

 Evaluation of apically extruded debris during endodontic retreatment

 Introduction: A growing interest to preserve teeth into the mouth by patients resulted in the increasing number of endodontic retreatments, and when these happen, many different types of irritants are extruded thro...

 Clinical, microbiological and radiographic considerations observed around dental implants

 Introduction: Periimplantitis is characterized by the inflammation of the soft tissues, bleeding, and suppuration, as well as rapid bone loss around dental implants that are in function. The lesion is associated wi...

Evaluation of the teratogenic potential of chloramphenicol to induce the appearance of cleft palate in Wistar rats

Introduction: Chloramphenicol is an antibiotic with controversial use during pregnancy for easily crossing the placental barrier and achieving high concentrations in the fetus. Objective: The aim of this study was to eva...

Download PDF file
  • EP ID EP125008
  • DOI -
  • Views 154
  • Downloads 0

How To Cite

João Marcelo Teixeira, Myrna Barcellos, Marco André Pinho, Carlos Augusto Barbosa, Rivail Fidel, Sandra Fide (2012). Effectiveness of an electronic apex locator used after preflaring of cervical and middle third. RSBO, 9(2), 158-162. https://europub.co.uk/articles/-A-125008