Effects of Grid Disturbances on Current Source Rectifier Controlled by FCS-MPC Algorithm

Journal Title: Power Electronics and Drives - Year 2017, Vol 2, Issue 2

Abstract

Nowadays, the increasing number of non-linear loads influences the grid, causing grid voltage disturbances. These disturbances may be very dangerous for the equipment and can create faults in converter behaviour. However, the right control algorithm can improve the reliability of the work. For a current source rectifier, the finite control set model predictive control has been proposed. This method is very flexible because of the variety of the possible cost function forms. It has been examined under grid voltage disturbed by the higher harmonics and the voltage drop. Simulation results prove the ability to damp the distortions and to ensure the unity power factor. Summing up, the algorithm is a very good solution for use in applications such as battery charging, active power filtering and low-voltage direct current load feeding.

Authors and Affiliations

Keywords

Related Articles

FINITE-ELEMENT ANALYSIS OF ACCIDENTAL ENERGIZING OF AN OFF-LINE TURBOGENERATOR

Background: Presented article shows the computation results of accidental off-line turbogenerator energizing. Inadvertent energizing of turbogenerator has been a particular issue in the power plant. The investigated case...

PARAMETRIC - ACTIVE COMPENSATION OF EARTH FAULT CURRENT IN IT-TYPE NETWORK

Parametric-active compensation of earth leakage currents minimalized virtual capacitance current in ships IT-type network is discussed. The protection is based on automatic compensation of leakage earth currents. The pro...

Smart Grid Condition Assessment: Concepts, Benefits, and Developments

Background: In this paper, condition assessment of electric grid assets will be discussed and illustrated within the context of smart grid principle. This paper aims to add significant contribution to a smart grid theory...

EMC REQUIREMENTS FOR POWER DRIVE SYSTEMS

The article presents electromagnetic compatibility requirements for immunity tests and the determination of the emission levels of electromagnetic disturbances in adjustable speed power drive systems. The dis-turbances a...

Performance Study of a New High Instantaneous Power Impulse Converter With Switched Capacitor Unit

Background: There is a large number and many different types converters in power electronics. There is a group of impulse converters and there is High Instantaneous Power Impulse Converter (HIPIC) among them. It is widel...

Download PDF file
  • EP ID EP407976
  • DOI 10.2478/pead-2018-0019
  • Views 58
  • Downloads 0

How To Cite

(2017). Effects of Grid Disturbances on Current Source Rectifier Controlled by FCS-MPC Algorithm. Power Electronics and Drives, 2(2), -. https://europub.co.uk/articles/-A-407976