Effects of Temperature and Humidity on Laser Diffraction Measurements to Jet Nebulizer and Comparison with NGI

Journal Title: AAPS PharmSciTech - Year 2016, Vol 17, Issue 2

Abstract

Laser diffraction (LD) and next generation impactor (NGI) are commonly used for the evaluation of inhaled drug formulations. In this study, the effect of temperature and humidity on the assessment of the nebulizer particle size distribution (PSD) by LD was investigated, and the consistency between NGI and LD measurements was evaluated. There was an increase in particle size with higher temperature or lower humidity. The particle population with a diameter less than 1 μm was significant at a temperature of 5°C or at relative humidity >90%; however, the same particle population became undetectable when temperature increased to 39°C or at relative humidity of 30–45%. The results of the NGI and LD measurements of aerosol generated from three types of jet nebulizers were compared. A poor correlation between the NGI and LD measurements was observed for PARI LC (2.2 μm) (R 2 = 0.893) and PARI LC (2.9 μm) (R 2 = 0.878), while a relatively good correlation (R 2 = 0.977) was observed for the largest particle size nebulizer (PARI TIA (8.6 μm)). We conclude that the ambient environment and the nebulizer have significant impacts on the performance and consistency between these instruments. These factors should be controlled in the evaluation of inhaled aerosol drug formulations when these instruments are used individually or in combination.

Authors and Affiliations

Xinghan Song, Junhua Hu, Shuyao Zhan, Rui Zhang, Wen Tan

Keywords

Related Articles

Simultaneous Determination of Acetaminophen and Synthetic Color(s) by Derivative Spectroscopy in Syrup Formulations and Validation by HPLC: Exposure Risk of Colors to Children

Analytical reagent grade sodium hydroxide and concentrated hydrochloric acid were procured from Qualigens, Mumbai, India. Methanol and acetonitrile (HPLC grade) were purchased from Merck Limited, Mumbai, India. The stand...

Development and Optimization of Gastro-Retentive Controlled-Release Tablet of Calcium-Disodium Edentate and its In Vivo Gamma Scintigraphic Evaluation

Medical management of heavy metal toxicity, including radioactive ones, is a cause for concern because of their increased use in energy production, healthcare, and mining. Though chelating agents like EDTA and DTPA in pa...

A Novel Topical Targeting System of Caffeine Microemulsion for Inhibiting UVB-Induced Skin Tumor: Characterization, Optimization, and Evaluation

The purpose of the present study was to develop an optimal microemulsion (ME) formulation as topical nanocarrier of caffeine (CAF) to enhance CAF skin retention and subsequently improve its therapeutic effect on UVB-indu...

Enhancing the Antitumor Activity of Berberine Hydrochloride by Solid Lipid Nanoparticle Encapsulation

Berberine hydrochloride (BH) is an isoquinolin alkaloid with promising anticancer efficacies. Nevertheless, further development and application of this compound had been hampered by its poor aqueous solubility, low gastr...

Design and Evaluation of a Novel Felbinac Transdermal Patch: Combining Ion-Pair and Chemical Enhancer Strategy

The aim of this study was to design a novel felbinac (FEL) patch with significantly higher (P < 0.05) skin permeation amount than the commercial product SELTOUCH® using ion-pair and chemic...

Download PDF file
  • EP ID EP682157
  • DOI  10.1208/s12249-015-0346-5
  • Views 101
  • Downloads 0

How To Cite

Xinghan Song, Junhua Hu, Shuyao Zhan, Rui Zhang, Wen Tan (2016). Effects of Temperature and Humidity on Laser Diffraction Measurements to Jet Nebulizer and Comparison with NGI. AAPS PharmSciTech, 17(2), -. https://europub.co.uk/articles/-A-682157