Efficacy and Safety of Different Energy Settings for Atrial Fibrillation Ablation using the Duty-cycled Radiofrequency Ablation Catheter (PVAC)

Journal Title: Journal of Cardiovascular Medicine and Cardiology - Year 2014, Vol 1, Issue 1

Abstract

In recent years, new ablation catheters have been developed to facilitate atrial fibrillation (AF) ablation procedures, including the multi-electrode pulmonary vein ablation catheter (PVAC), capable of using different proportions of unipolar and bipolar energy. The purpose of this study was to evaluate the acute efficacy, as well as safety, when using the two different energy settings for the PVAC catheter. Methods and Results: Thirty-five patients with a mean age of 627.7 years with paroxysmal (54%) or persistent AF were included in the study and randomized to 4:1 versus 2:1 bipolar/unipolar energy setting with the PVAC device. The mean number of applications with the PVAC catheter was 41 and 51 15 (p = 0.3) respectively with the 4:1 and the 2:1 setting. Touch-up with another RF ablation catheter was necessary in 3 and 7 patients respectively in the 4:1 and 2:1 group. The procedure time was 15535 and 174minutes respectively and the total fluoroscopy time, including the time for touch-up with another catheter, was 4214 and 5017 minutes respectively with the 4:1 versus 2:1 setting. No complications were seen in any group. Conclusion: There was no significant difference between the 4:1 and 2:1 bipolar-to-unipolar energy setting with the PVAC regarding the number of applications needed to create (PVI), the number of patients in which (PVI) could be achieved without touch-up applications, the procedure time or the fluoroscopy time.

Authors and Affiliations

Stefan Lönnerholm, Helena Malmborg, Per Blomström, Carina Blomström-Lundqvist

Keywords

Related Articles

Hydrogels for Cardiac Tissue Repair and Regeneration

The main cause of death in the world continues to be cardiovascular disease, which affects annually over 900,000 people and in the entire word approximately 50% of the people suffering myocardial infarction (MI) die with...

Spontaneous Coronary Artery Dissection and Implantation of Absorb Bioresorbable Drug-Eluting Stent in Cocaine-Related Acute Coronary Syndrome

The spontaneous dissection of the coronary arteries (SCAD) is rare and few data are available in the worldwide literature. Several diseases and conditions have been associated with SCAD, such as atherosclerosis, connecti...

Disparity between estimates and measures of maximum heart rate in pilots with coronary artery disease

Background : Several studies indicate that HRmax estimates using the traditional equation, HRmax = 220 - Age, may represent a regression slope and intercept that does reflect the true relationship between age and maximal...

An Anusual Cause of Secondary Hypertension in a Young Man

Mr F.P., a 33-y/o man consulted after 3 months of general status alteration with a loss of 7 kgs and nocturnal sweats. His blood pressure was controlled up to 190/110 mmHg. Clinical examination by general pratictioner wa...

The pathophysiology of chronic cardiorenal disease based on central hemodynamics

As patients with chronic kidney disease (CKD) and chronic heart failure (CHF) increase, there is concern about a future heart failure pandemic. Deterioration of renal function is an independent prognostic factor for CHF...

Download PDF file
  • EP ID EP231216
  • DOI 10.17352/2455-2976.000002
  • Views 102
  • Downloads 0

How To Cite

Stefan Lönnerholm, Helena Malmborg, Per Blomström, Carina Blomström-Lundqvist (2014). Efficacy and Safety of Different Energy Settings for Atrial Fibrillation Ablation using the Duty-cycled Radiofrequency Ablation Catheter (PVAC). Journal of Cardiovascular Medicine and Cardiology, 1(1), 7-10. https://europub.co.uk/articles/-A-231216