Efficacy and Safety of Different Energy Settings for Atrial Fibrillation Ablation using the Duty-cycled Radiofrequency Ablation Catheter (PVAC)
Journal Title: Journal of Cardiovascular Medicine and Cardiology - Year 2014, Vol 1, Issue 1
Abstract
In recent years, new ablation catheters have been developed to facilitate atrial fibrillation (AF) ablation procedures, including the multi-electrode pulmonary vein ablation catheter (PVAC), capable of using different proportions of unipolar and bipolar energy. The purpose of this study was to evaluate the acute efficacy, as well as safety, when using the two different energy settings for the PVAC catheter. Methods and Results: Thirty-five patients with a mean age of 627.7 years with paroxysmal (54%) or persistent AF were included in the study and randomized to 4:1 versus 2:1 bipolar/unipolar energy setting with the PVAC device. The mean number of applications with the PVAC catheter was 41 and 51 15 (p = 0.3) respectively with the 4:1 and the 2:1 setting. Touch-up with another RF ablation catheter was necessary in 3 and 7 patients respectively in the 4:1 and 2:1 group. The procedure time was 15535 and 174minutes respectively and the total fluoroscopy time, including the time for touch-up with another catheter, was 4214 and 5017 minutes respectively with the 4:1 versus 2:1 setting. No complications were seen in any group. Conclusion: There was no significant difference between the 4:1 and 2:1 bipolar-to-unipolar energy setting with the PVAC regarding the number of applications needed to create (PVI), the number of patients in which (PVI) could be achieved without touch-up applications, the procedure time or the fluoroscopy time.
Authors and Affiliations
Stefan Lönnerholm, Helena Malmborg, Per Blomström, Carina Blomström-Lundqvist
Efficacy and Safety of Different Energy Settings for Atrial Fibrillation Ablation using the Duty-cycled Radiofrequency Ablation Catheter (PVAC)
In recent years, new ablation catheters have been developed to facilitate atrial fibrillation (AF) ablation procedures, including the multi-electrode pulmonary vein ablation catheter (PVAC), capable of using different pr...
How the New International recommendation for Electrocardiographic interpretation in Athletes would change our practice
Recent evidences in the prevention of sudden cardiac death (SCD) confirmed the importance of pre-participation cardiovascular screening in athletes to early identify, and further disqualify from the competition, all the...
Valsalva Maneuver in diastolic heart failure, diastolic dysfunction and systolic heart failure clinically BNP and echocardiography
Background: Valsalva maneuver one of the oldest method to diagnose heart failure, it’s cheap ,non-invasive ,bedside tool .Its well-studied in systolic heart failure patients which showed abnormal response either square w...
An Updated Systematic Review and Meta-analysis of the Short- and Long-term Outcomes of Percutaneous Coronary Intervention for Patients with Severe Left Ventricular Systolic Dysfunction
Background: Coronary artery disease (CAD) is the most common cause of left ventricular dysfunction (LVD). Confl icting evidence exists with regards to available treatments and patient prognosis. Revascularization may imp...
Bleeding Risk under Oral Factor Xa Inhibitors: Meta-analysis of the randomized comparison with Vitamin K Antagonists and Meta-Regression analysis
Background: Randomized trials have shown that oral direct factor Xa inhibitors (ODIXa) offer potential advantages over vitamin K antagonists (VKAs). It is however unclear whether the magnitude of their benefit is similar...