ЕКСПЕРИМЕНТАЛЬНІ ДОСЛІДЖЕННЯ ЗАЛЕЖНОСТІ ВИМІРЮВАНОЇ ТЕМПЕРАТУРИ ВІД ЧАСТОТИ АНТИСТОКСОВОЇ КОМПОНЕНТИ СПЕКТРА КОМБІНАЦІЙНОГО РОЗСІЮВАННЯ СВІТЛА ДЛЯ AL2O3
Journal Title: Вимірювальна техніка та метрологія - Year 2016, Vol 1, Issue 77
Abstract
On the basis of Raman known at present are two ways to measure temperature. The first and most more common method of measuring temperature by Raman intensity is dependent stokes and antistokes Raman component. This method is relatively simple to implement, since change with temperature integrated area antistokes and stokes component. This method of temperature measurement by Raman has good sensitivity and accuracy, but has several significant drawbacks. The main drawback is a methodological error that occurs as a result of determining the area of integrated antistokes and Stokes components. Spectrophotometer to measure consistently first Stokes then antistokes component of Raman spectroscopy, the measurement time of stokes components of the object and is heated by laser heating antistokes components that it leads to error. Another way is to measure the frequency shift Raman. To measure the temperature shift frequency Raman enough to determine just antistokes component Raman spectroscopy. To measure the temperature shift frequency Raman frequency is not appropriate to use a spectrophotometer and spectrum analyser. The peculiarity of the spectrum analyser is that it measures only antistokes component, and the full range of a whole, not just a stepping stone that can reduce the methodological error. Also unconditional significant advantage of this method within the temperature measurement by Raman is speed. By comparison when measuring the temperature integrated area ratio of the maximum speed is 13 seconds, and the Raman shift frequency of 1 second. By reducing the measurement time is reduced further methodological error caused by heating of the object studied laser. Therefore, based on this method conducted research described in the article. The results of experimental studies Raman spectroscopy for Al2O3 in the temperature range of 18 to 70 °C. Each point temperature for 10 implementations derived components range antistokes Raman method of centre of mass calculated value equivalent frequency components antistokes Raman spectroscopy, and the average value of the equivalent frequency components antistokes range and uncertainty determine an equivalent frequency components antistokes. Analytical dependences equivalent frequency components antistokes Raman spectrum of temperature. The dependence of error of approximation of the number of coefficients approximating curve for each of the objects, and certainly the best number of factors. Equipment using experiments were conducted: laser ν = 632,9 nm spectrum analyser MS 3501i, optical circuit using a narrow band filter and prism, studies were conducted under normal conditions.
Authors and Affiliations
Юрій Кривенчук, Ігор Микитин, Олег Сегеда
СПЕКТРАЛЬНІ МЕТОДИ В КВАЛІМЕТРИЧНИХ ДОСЛІДЖЕННЯХ
Peculiarities of spectral method application aimed at detecting qualimetry object properties in the different frequency ranges of electro-magnetic waves are under consideration.
НОРМАТИВНІ ВИМОГИ ЩОДО КОНТРОЛЮ ПАРАМЕТРІВ КОРОЗІЙНОГО СТАНУ ПІДЗЕМНИХ ТРУБОПРОВОДІВ
Recommendations in relation to combination in the normative document of requirements in relation to control of degree of security of underground pipelines from steel in a corrosive environment from positions of electroch...
Прогнозування та реалізація термоелементів на основі термометричного матеріалу Zr1-xErxNiSn
The temperature and concentration dependencies of resistivity, thermopower and also power descriptions of Zr1-xErxNiSn semiconductor in ranges, T = 80 ¸ 380 K and x = 0 ¸ 0,50, respectively were investigated.
КОНТРОЛЬ ЯКОСТІ ПИТНОЇ ВОДИ ЗА ЕЛЕКТРИЧНИМИ ПАРАМЕТРАМИ
In the article it is investigated the method of quality control of drinking water on the electrical parameters with the use of two electrode electrolytic cell. Is carried out the analysis of equivalent circuit and the er...
Розумні вимірювальні засоби для кіберфізичних систем
Smart measuring instruments are the prerequisite for CPS design as they constitute the essential units of informationmeasuring subsystems. There is a set of smart measurement instruments which is divided into the followi...