Enhancement of Power Quality in Distribution System Using D-STATCOM
Journal Title: International Journal for Research in Applied Science and Engineering Technology (IJRASET) - Year 2016, Vol 4, Issue 3
Abstract
Sensitive loads are greatly affected by power-quality (PQ) disturbances in the system. Power quality problems such as voltage sag and harmonic distortion along with reliability issues are some major concern and in this work the voltage distortion & reactive power issues are considered. Inverters based on Voltage Source Converters (VSC) are widely used as a basic component in custom power devices. These controllers produce voltage harmonics due to switching operation of power electronic converters. The proposed controller supplements the voltage-sag compensation control of the statcom. It does not require phaselocked loop and independently controls the magnitude and phase angle of the injected voltage for each phase. The proposed scheme have the following advantages such as limit the fault current , interrupt the fault current within two cycles, interrupt the fault current during arching fault and low dc link voltage. The circuit will be simulated using MATLAB.
Authors and Affiliations
Mr. M. Kamalakkannun, Mr. P. Arulkumar, D. Jasmine Susila
This Novel Realize New Electronic Capsule
This work will speak to the confront to smooth the progress of the development of a high capacity radio system for a small, miniaturized electronic pill device that can be saleable or implantable in human body in order...
The Experimental Study of Heat Transfer Coefficient of Al2o3/Water Nano Fluid by Using Double Pipe Heat Exchanger
The heat transfer coefficient of Al2O3/Water nanofluid is investigated experimentally in this paper. This Experiment is done with the help of double pipe heat exchanger. The Al2O3 nanofluid is prepared by dispersing an...
A Highly Auto Configuration for A Node Using Addressing Protocol in Ad Hoc Networks
The addressing configuration may be a key challenge in networks owing to the shortage of infrastructure. Autonomous addressing protocols need a distributed and self-managed mechanism to avoid address collisions in an ex...
Comparative Study And Control System Design For 4 Level Tank Systems (Non-Linear) Using Pid And Brain Emotional Learning Based Intelligent Controller
Adaptive control systems have been always under extensive modern research. It has great importance in modern control systems. A lot of intelligent controllers have been modeled and are in use in modern control systems a...
Performance Evaluation of Effluent Treatment Plant of Dairy Industry in Gwalior (M.P.).
Dairy industries are generally considered to be the largest source of wastewater in many countries. Although they are not commonly associated with severe environmental problems, they must continually consider their envi...