Еnhancement of reliability and efficiency of cooling towers of nuclear power plants

Abstract

Present paper contains results of Rivne nuclear power plant cooling towers testing to define their cooling efficiency change during continuous service by means of comparing the actual temperature of cooled water with the calculated value defined based on technological performance determined for previous testing period. In order to determine the possibility of increasing the cooling efficiency of cooling towers, the effect of extra increase of cooling tower wetting surface on the performance of the tower has been investigated. The influence of antifreezing heater on water cooling in the cooling towers in summer has been detected. It was ascertained that cooling efficiency of the cooling towers decreased in comparison with previous testing period due to the deterioration of uniformity of wetting with cooling water by the sprinklers of the towers. This is caused by clogging and breakdown of insufficiently effective and weak sprinkling nozzles. We managed to achieve the increase of cooling efficiency of cooling towers by means of their wetting surface increase, as well as unorganized cooling water leakage reducing. This enabled to ensure more uniform feed of cooling water on the tower packing and to reduce water temperature.

Authors and Affiliations

J. S. Mуsak, M. Ya. Kuznetsova, T. E. Rymar, F. D. Matiko

Keywords

Related Articles

The properties of time-frequency localization of basis functions used in OFTDM communication systems

This article investigates the properties of time-frequency localization (TFL) of various basis functions, such as rectangular function, the function of half cosine, isotropic orthogonal transform algorithm (IOTA) functio...

Automation of arches calculation

The procedure of automation of calculation of the strained-deformed state of circular arches is considered in the calculation of bending and tensile-compression deformations concentrated and distributed external loads. T...

Thermal hydraulic analysis of the regimes with unmanageable control rods movement and ejection for the reactor strength estimation

The article presents results of research (thermal-hydraulic analysis) of initiating events (regulatory regimes), associated with the uncontrolled movement and ejection of control rods that had previously not been conside...

Influence of organic ligands on copper electrodeposition from mono- and polyligand electrolytes

It is important to know the laws of copper electrodeposition from low-concentrated electrolytes containing different ligands because they simulate components of various copper-containing liquid wastes and electrolytes fo...

Application of the statistical approach in diagnosing in medical and biological researches

The task of diagnosis in biomedical research in a number of cases can be solved using a statistical approach. Current research is the possibility of using statistical analysis to diagnose the state of the human respirato...

Download PDF file
  • EP ID EP311771
  • DOI 10.15276/opu.3.53.2017.07
  • Views 168
  • Downloads 0

How To Cite

J. S. Mуsak, M. Ya. Kuznetsova, T. E. Rymar, F. D. Matiko (2017). Еnhancement of reliability and efficiency of cooling towers of nuclear power plants. Праці Одеського політехнічного університету, 3(53), 54-58. https://europub.co.uk/articles/-A-311771