Estimation of repeatability of the reference position in the instrumental analysis of the temporomandibular joints.
Journal Title: Prosthodontics - Year 2011, Vol 61, Issue 3
Abstract
Diagram of Posselt is showing graphical movements of mandible. In the horizontal plane shows the difference between the positioning of incisal point in central occlusion (ICP) and retruded contact position. With retruded contact position is connected term reference position which is a reference to the clinical relationship of the mandible. This term means the position of the mandible reached through her conduct to the retruded position, in which movement in the joints of the temporomandibular joint (TMJ) is a pure rotation around his stabile hinge axis. This is the starting position for the clinical functional analysis.Aim of the studyAim of the study was to estimate the repeatability of the reference position as a clinical position of the mandible for instrumental analysis of TMJ function.Materials and methods.The study was performed in 10 patients with complete dental arches. Determined position of the reference method proposed by Slaviček and recorded using the Compact Cadiax. Registration of the position of mandible was by using the silicone material. Reference position was recorded using Arcus Digma in position registrated by silicon material. All measurements were made three times.ResultsThe repeatability of all three measurements were obtained in 3 patients, in 5 cases, consistent results were after 2, and 2 patients - all measurements differed.ConclusionProposed by Slaviček method for determining clinical reference position is repeatable to an extent sufficient to perform according to the instrumental analysis of TMJ function
Authors and Affiliations
Jolanta Loster, Aneta Wieczorek, Stanisław Majewski
Wpływ powtórnego topienia stopów CoCr stosowanych w protetyce stomatologicznej na cytotoksyczność fibroblastów dziąsła ludzkiego
Cel pracy. Celem badań była ocena wpływu powtórnego topienia powszechnie używanych w protetyce stomatologicznej stopów Wironit extrahard (Wr) i Wirobond C (WbC) oraz odlewów wykonanych z różnym udziałem stopu powtórnie t...
Experimental measurements for the numerical simulation verification of mechanical actions of upper alar chrome-cobalt partial denture with separated kinematics
Introduction. The verification of the numerical representation of mechanical actions of alar frame chrome-cobalt partial denture with separated saddle kinematics required the metrological evaluation of experimental measu...
Analysis of fitness of prosthetic bridge designed and produced with digital methods
Introduction. In recent years the digitalization of dentistry has taken a special place in the world of scientific research. With the development of scanning methods and the improvement of software for the analysis and...
Korony teleskopowe jako element retencyjny protez ruchomych wspartych o implanty – przegląd piśmiennictwa
Porównanie odporności na złamania koron monolitycznych cienkościennych i pełnokonturowych z ceramik tlenku cyrkonu
Wstęp. Korony monolityczne, pełnokonturowe z tlenku cyrkonu stają się alternatywą dla koron złożonych, konwencjonalnych opartych na rdzeniu z tlenku cyrkonu w zębach bocznych. Wymagają znacznie mniejszego opracowania tk...