ESTIMATION OF SYSTEM RELIABILITY FOR LOG – LOGISTIC DISTRIBUTION

Journal Title: Journal of Atoms and Molecules - Year 2012, Vol 2, Issue 2

Abstract

A multicomponent system of k components having strengths following k- independently and identically distributed random variables 1 2 k y , y ,....,y and each component experiencing a random stress X is considered. The system is regarded as alive only if at least s out of k (s<k) strengths exceed the stress. The reliability of such a system is obtained when strength, stress variates are given by log-logistic distribution with different scale parameters. The reliability is estimated using Moment Method, ML method, Modified ML methods and best linear unbiased method of estimation in samples drawn from strength and stress distributions. The reliability estimators are compared asymptotically. The small sample comparison of the reliability estimates is made through Monte Carlo simulation.

Authors and Affiliations

G. Srinivasa Rao

Keywords

Related Articles

SYNTHESIS AND CHARACTERIZATION OF VARIOUS 3-[3,5-BIS (TRIFLUOROMETHYL)PHENYL]-5-(SUBSTITUTED PHENYL)-1,2-ISOXAZOLE

Some novel heterocyclic compounds containing isoxazole ring systems were prepared from various chalcones. The synthesized compounds have been characterized by elemental analysis and spectral methods

EXAMINATION OF VOLLYBALL GAME VERSUS AEROBIC EXCERCISES IN THE MITIGATING OF THE STRESS

This study investigated the influence of eight-week volleyball game versus aerobic exercise interventions in mitigating of stress in the young people. The first 51persons from100 participates who had more stress score th...

REACTION OF HYDRAZINE HYDRATE AND HYDRAZINE HYDROCHLORIDE WITH DIBENZOYLMETHANE AND FLAVONE: ROLE OF SOLVENT AND pH ON FORMATION OF PRODUCTS

Selection of solvent and pH of the reaction mixture are important for the formation of desired products. Ethanol and DMF as reaction medium, pH was kept either basic (pH 10) or acidic (pH 4). Hydrazine hydrate and hydraz...

LIQUID CHROMATOGRAPHY METHOD DEVELOPMENT AND VALIDATION FOR ANALYSIS OF CLONIDINE IN PHARMACEUTICAL DOSAGE

A new simple, rapid, selective, precise and accurate isocratic reverse phase high performance liquid chromatography assay has been developed and validated for the estimation of CLONIDINE in tablet formulation. The separa...

Download PDF file
  • EP ID EP367498
  • DOI -
  • Views 89
  • Downloads 0

How To Cite

G. Srinivasa Rao (2012). ESTIMATION OF SYSTEM RELIABILITY FOR LOG – LOGISTIC DISTRIBUTION. Journal of Atoms and Molecules, 2(2), 182-190. https://europub.co.uk/articles/-A-367498