Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements

Journal Title: Journal of Biomedical Physics and Engineering - Year 2018, Vol 8, Issue 3

Abstract

Aims: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured results obtained from gafchromic film EBT2. Materials and Methods: Authors employed kailwood (Pinus Wallichiana) to mimic lung. Briefly, seven Kailwood plates, each measuring 25x25 cm2 of varying thicknesses totaling 13 cm equivalent to the mean thickness of an adult human lung, were sandwiched between 5 cm tissue equivalent material from top and 10 cm below. Physical measurements were performed using Radiochromic film EBT2. The field sizes of 1x1, 2x2, 5x5 and 10x10 cm2 were selected at 100 cm SSD. Simulations were performed using EGSnrc/DOSRZnrc Monte Carlo code. The dose variation inside the inhomogeneity and near the interface was calculated using AAA & XVMC algorithm. Results: Preliminary results show that there is large variation of dose inside inhomogeneity. The maximum variation of dose inside the inhomogeneity for 1x1 cm2 was found 40% by AAA and 4.5% by XVMC compared to measured/simulated results. For the field size of 2x2 cm2 , these figures were 27% by AAA & 3.5% by XVMC. For 5x5 cm2 field size, the variation is small which becomes insignificant for larger fields. Conclusion: The results presented in this work indicate that for smaller fields, XVMC algorithm gives more realistic prediction, while there is the need for caution on using AAA algorithm for dose calculations involving small area irradiation encompassing heterogeneities and low-density media.

Authors and Affiliations

N. Singh, N. K. Painuly, L. N. Chaudhari, A. Chairmadurai, T. Verma, D. Shrotiya, C. P. Bhatt

Keywords

Related Articles

Parametrization of Pedestrian Injuries and its Utilisation in Proving Traffic Accidents Course Using Injury Signatures and Contact Signatures

Background: The paper points out the present limited possibility of using the verbal description of injuries for the needs of experts from the field of road transportation as relevant criminalistics traces, as well as th...

MRS Shimming: An Important Point Which Should not be Ignored

Background: Proton magnetic resonance spectroscopy (MRS) is a well-known device for analyzing the biological fluids metabolically. Obtaining accurate and reliable information via MRS needs a homogeneous magnetic field in...

Neural Network-Based Learning Kernel for Automatic Segmentation of Multiple Sclerosis Lesions on Magnetic Resonance Images

Background: Multiple Sclerosis (MS) is a degenerative disease of central nervous system. MS patients have some dead tissues in their brains called MS lesions. MRI is an imaging technique sensitive to soft tissues such as...

A Monte Carlo Study on Dose Enhancement by Homogeneous and Inhomogeneous Distributions of Gold Nanoparticles in Radiotherapy with Low Energy X-rays

Background: To enhance the dose to tumor, the use of high atomic number elements has been proposed. Objective: The aim of this study is to investigate the effect of gold nanoparticle distribution on dose enhancement in t...

Radiation-induced Non-targeted Effect and Carcinogenesis; Implications in Clinical Radiotherapy

Bystander or non-targeted effect is known to be an interesting phenomenon in radiobiology. The genetic consequences of bystander effect on non-irradiated cells have shown that this phenomenon can be considered as one of...

Download PDF file
  • EP ID EP455520
  • DOI -
  • Views 85
  • Downloads 0

How To Cite

N. Singh, N. K. Painuly, L. N. Chaudhari, A. Chairmadurai, T. Verma, D. Shrotiya, C. P. Bhatt (2018). Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements. Journal of Biomedical Physics and Engineering, 8(3), 223-230. https://europub.co.uk/articles/-A-455520