EVALUATION OF ACCURACY OF THE BODY COMPOSITION MEASUREMENTS BY THE BIA METHOD

Journal Title: Human Movement - Year 2011, Vol 12, Issue 1

Abstract

Purpose. The main purpose of this study is to verify the accuracy of body composition measurements by the BIA method, using TANITA 418 MA unit. Basic procedures. For purposes of our study we decided to use the type-A uncertainty evaluation method (statistical processing of measured data). To formulate diagnostic error for the BIA method we used typical (standard) error of measurement from differences between pairs of repeated measurements – which is in principle a mean error of the test. The research was carried out on a group of 10 students whose field of study is physical education and sport. These students were chosen from the total number of 74 students in such a way that they represent as wide range of fat fraction as possible. Representation of their fat fraction oscillated between 9.0 to 31.2% of body fat. Input value of body fat, which was the basic criterion for selection of students to the measurement etalon, was determined by the DEXA method. Main findings. We described the uncertainty (type A) in selected file of etalons by an average value and by a standard deviation in percentage of fat: 0.13 ± 0.05. A diagnostic error of the method expressed by means of typical (standard) error of measurement was 0.38% of body fat. Conclusion. Considering the detected values of uncertainty (type A) and of typical error of measurement, we can conclude that measurement of body composition by the BIA method using TANITA 418 MA unit is sufficiently accurate for requirements of practical use. The necessary condition for the above mentioned measurement accuracy is a strict observance of standard measurement conditions.

Authors and Affiliations

Petr Kutáč, Vojtěch Gajda

Keywords

Related Articles

INTRA- AND INTER-EXAMINER RELIABILITY IN ANGULAR MEASUREMENTS OF THE KNEE WITH A SMARTPHONE APPLICATION

Purpose. Goniometric smartphone applications to measure joint angles offer greater practicality and accessibility, which makes them potential alternatives to a conventional goniometer. The aim of the present study was to...

The differences in fat accumulation and distribution in female students according to their level of activity

Purpose. The appropriate percentage of body fat is essential for women’s health and biological condition. Both accumulation of fat and distribution pattern of adipose tissue are connected with health risk, which justifie...

A NOVEL INTERVENTION PROGRAM (CRICFIT) FOR THE STRENGTH AND CONDITIONING OF ADOLESCENT CRICKET PLAYERS

Purpose. The purpose of the current investigation was to examine the effects of a 4-week field-based intervention program (CricFit) on general fitness, with the program designed to reflect the demands of the game in an a...

Seasonal variations in the morphological and functional development of girls and boys aged 14–15

Purpose. During a biological year one can observe the effects of seasonal change on the number of functions and processes in the human organism. The rhythmical seasonal changes of a year are directly connected with a num...

Laterality of lower limbs during V2 Alternate in Nordic combined athletes

Purpose. The aim of this study was to analyse the foot pressure distribution by cross-country skiers during the push-off phase when using the V2 Alternate skating technique depending on lower limb preference. The study a...

Download PDF file
  • EP ID EP145408
  • DOI doi: 10.2478/v10038-010-0027-x
  • Views 108
  • Downloads 0

How To Cite

Petr Kutáč, Vojtěch Gajda (2011). EVALUATION OF ACCURACY OF THE BODY COMPOSITION MEASUREMENTS BY THE BIA METHOD. Human Movement, 12(1), 41-45. https://europub.co.uk/articles/-A-145408