Abstract

Concrete is a most commonly used material in the field of construction with high compressive strength but with low tensile strength. The advantage of concrete is that it is easily available, less costly and convenient to cast. Concrete structures are very susceptible to cracking which causes chemicals and water to penetrate in the concrete that degrades the concrete strength, thereby, decreasing the performance of the structure. To solve this problem, eco-friendly concrete is developed. This concrete is formed by inserting bacteria into normal concrete. The grown bacteria are added to the M-25 concrete. The main motive of this research work is to measure the performance of the concrete by the microbiologically induced unique growth or filler. One such contemplation has lead to the improvement of a very unique concrete known as Bacterial Concrete where bacteria is induced in the cement and concrete to heal up the cracks. In this research, numbers of tests are performed on normal concrete and bacterial concrete for 7, 14, and 28 days. To determine the accuracy of the bacterial concrete, parameters such as water absorption, compressive strength, Ultrasonic pulse velocity test (UPVT), Flexural test and slump test are measured.

Authors and Affiliations

Er. Simranjit Singh Raina, Er. Sandeep Singla, Dr. VS Batra

Keywords

Related Articles

Emission and Performance testing of single cylinder CI engine with using ricebran biodiesel

The rate of petroleum reserve is declining while energy demand keeps increasing. The current expansion of the Indian economy has escalated petroleum demand, prices have surged, hurting the economies of poor and developin...

Strengthening of R.C. Beams Using Different Techniques

Experimental program consisting of five reinforced concrete beams with dimensions 2200 mm length, 150 mm width, 200 mm depth and reinforced by 2 16 bottom RFT, 212 upper RFT and 58/m stirrups, were carried out to inve...

Fire Resistance Potentials of Structural Timbers

Fire resistance/endurance potential of structural timbers was investigated. The experiment was carried out as what the case may be under natural burning flame at varying interval of time. From the result obtained and ana...

Reduction in Scratches & Edge Wrinkles Defects in CRM

The Rolling is mostly used metal forming process due to its greater production and great control of finished products. . In the present competitive situation in this world we need to improve our areas in order to stay in...

Evaporation Control Technique in Open Reservoirs: An Overview and Assessment Study

Global warming and the increasing concentration of greenhouse gases in the atmosphere will affect temperature and rainfall.This rise in temperature ultimately results in evaporation losses from storage reservoirs. As wat...

Download PDF file
  • EP ID EP438547
  • DOI 10.9790/1684-1505030106.
  • Views 59
  • Downloads 0

How To Cite

Er. Simranjit Singh Raina, Er. Sandeep Singla, Dr. VS Batra (2018). Evaluation of Bacillus Subtilis Bacterial Concrete with Normal Concrete. IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE), 15(5), 1-6. https://europub.co.uk/articles/-A-438547