Evaluation of Blood Parameters Alteration Following Low-dose Radiation Induced by Myocardial Perfusion Imaging
Journal Title: Journal of Biomedical Physics and Engineering - Year 2018, Vol 8, Issue 2
Abstract
Introduction: With increasing the usage of myocardial perfusion imaging (MPI) for the diagnosis of ischemic heart disease, we aimed to evaluate the side effects of low-dose radiation induced by this technique on blood elements, especially proteins and liver function factors. Material and Methods: 40 eligible patients (Mean age: 54.62±10.35, 22 female and 18 male), who had referred to the nuclear medicine department for MPI from May till August 2014, were enrolled in the study. A blood sample was taken from each patient just before and 24 hours after the injection of 740Mbq of Tecnetium-99m Methoxy isobutyl isonitrile (99mTc-MIBI) in the rest phase of the MPI in a reference medical laboratory; blood tests included total protein (TP), albumin (Alb), globulin (Glo), aspartate aminotransferase (AST), alanine transaminase (ALT), alkaline phosphatase (ALP), direct bilirubin (D.Bili), total bilirubin (T.Bili), serum iron (SI), total iron bounding capacity (TIBC), Albumin globulin ratioA/G ratio), and complete blood count (CBC). Results: Injection of 740Mbq99mTc-MIBI caused a significant increase in serum levels of AST (p= 0.001), ALT (p= 0.001), SI (p= 0.030), TIBC (p= 0.003) and A/G Ratio (p= 0.020). However, following radiotracer injection, a significant decrease was noted in the serum levels of TP (p= 0.002), Alb (p= 0.014), Glo(p= 0.002), ALP (p= 0.001), D.Bili (p= 0.003) and T.Bili (p= 0.000). Conclusion: Due to increased usage of MPI, our data highlights the importance of monitoring the clinical and paraclinical effects of the procedure on vital organs and physiological pathways to reduce their adverse effects
Authors and Affiliations
M. S. Alavi, M. A. Okhovat, M. Atefi, F. Khajeh Rahimi, S. Mortazavi
Diagnosis of OCD Patients Using Drawing Features of Bender Gestalt Shapes
Background: Since psychological tests such as questionnaire or drawing tests are almost qualitative, their results carry a degree of uncertainty and sometimes subjectivity. The deficiency of all drawing test is that the...
Detection and Characterization of Human Teeth Caries Using 2D Correlation Raman Spectroscopy
Background: Carious lesions are formed by a complex process of chemical interaction between dental enamel and its environment. They can cause cavities and pain, and are expensive to fix. It is hard to characterize in viv...
Protective Effects of IMOD and Cimetidine against Radiation-induced Cellular Damage
Radiation damage is to a large extent caused by overproduction of reactive oxygen species (ROS). Radioprotectors are agents or substances that reduce the effects of radiation in healthy normal tissues while maintaining t...
Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams
Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measur...
Manipulation Effect on Lumbar Kinematics in Patients with Unilateral Innominate Rotation and Comparison with Asymptomatic Subjects
Background: Lumbar motion analysis is used as a clinical method in the diagnosis and treatment of low back pain (LBP). So far, no studies have shown if manipulating the sacroiliac joint (SIJ) will change spinal kinematic...