Evaluation of Blood Parameters Alteration Following Low-dose Radiation Induced by Myocardial Perfusion Imaging

Journal Title: Journal of Biomedical Physics and Engineering - Year 2018, Vol 8, Issue 2

Abstract

Introduction: With increasing the usage of myocardial perfusion imaging (MPI) for the diagnosis of ischemic heart disease, we aimed to evaluate the side effects of low-dose radiation induced by this technique on blood elements, especially proteins and liver function factors. Material and Methods: 40 eligible patients (Mean age: 54.62±10.35, 22 female and 18 male), who had referred to the nuclear medicine department for MPI from May till August 2014, were enrolled in the study. A blood sample was taken from each patient just before and 24 hours after the injection of 740Mbq of Tecnetium-99m Methoxy isobutyl isonitrile (99mTc-MIBI) in the rest phase of the MPI in a reference medical laboratory; blood tests included total protein (TP), albumin (Alb), globulin (Glo), aspartate aminotransferase (AST), alanine transaminase (ALT), alkaline phosphatase (ALP), direct bilirubin (D.Bili), total bilirubin (T.Bili), serum iron (SI), total iron bounding capacity (TIBC), Albumin globulin ratioA/G ratio), and complete blood count (CBC). Results: Injection of 740Mbq99mTc-MIBI caused a significant increase in serum levels of AST (p= 0.001), ALT (p= 0.001), SI (p= 0.030), TIBC (p= 0.003) and A/G Ratio (p= 0.020). However, following radiotracer injection, a significant decrease was noted in the serum levels of TP (p= 0.002), Alb (p= 0.014), Glo(p= 0.002), ALP (p= 0.001), D.Bili (p= 0.003) and T.Bili (p= 0.000). Conclusion: Due to increased usage of MPI, our data highlights the importance of monitoring the clinical and paraclinical effects of the procedure on vital organs and physiological pathways to reduce their adverse effects

Authors and Affiliations

M. S. Alavi, M. A. Okhovat, M. Atefi, F. Khajeh Rahimi, S. Mortazavi

Keywords

Related Articles

Monte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator

Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to im...

Solver Device for Powdery Drugs

Pharmacotherapy is a major treatment method in healthcare centers, and the injection of powdered drugs is among common pharmacotherapy techniques. Medication errors and nosocomial infections are among major health issues...

Adaptive Response Induced by Pre-Exposure to 915 MHz Radiofrequency: A Possible Role for Antioxidant Enzyme Activity

Background: Over the past few years, the rapid use of high frequency electromagnetic fields like mobile phones has raised global concerns about the negative health effects of its use. Adaptive response is the ability of...

Assessment of Adherence of Diagnostic Accuracy Studies Published in Radiology Journals to STARD Statement Indexed in Web of Science, PubMed & Scopus in 2015

Rationale and Objective: The objective of this study is to evaluate the methodological adherence of diagnostic accuracy studies published in radiology journals, which were indexed in different databases with the STARD st...

Evaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA

Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Electron specific absorbed fractions (SAF) values have had vital role in the assessment of absorbed dose. In past stu...

Download PDF file
  • EP ID EP453800
  • DOI -
  • Views 130
  • Downloads 0

How To Cite

M. S. Alavi, M. A. Okhovat, M. Atefi, F. Khajeh Rahimi, S. Mortazavi (2018). Evaluation of Blood Parameters Alteration Following Low-dose Radiation Induced by Myocardial Perfusion Imaging. Journal of Biomedical Physics and Engineering, 8(2), 179-184. https://europub.co.uk/articles/-A-453800