Evaluation of Blood Parameters Alteration Following Low-dose Radiation Induced by Myocardial Perfusion Imaging

Journal Title: Journal of Biomedical Physics and Engineering - Year 2018, Vol 8, Issue 2

Abstract

Introduction: With increasing the usage of myocardial perfusion imaging (MPI) for the diagnosis of ischemic heart disease, we aimed to evaluate the side effects of low-dose radiation induced by this technique on blood elements, especially proteins and liver function factors. Material and Methods: 40 eligible patients (Mean age: 54.62±10.35, 22 female and 18 male), who had referred to the nuclear medicine department for MPI from May till August 2014, were enrolled in the study. A blood sample was taken from each patient just before and 24 hours after the injection of 740Mbq of Tecnetium-99m Methoxy isobutyl isonitrile (99mTc-MIBI) in the rest phase of the MPI in a reference medical laboratory; blood tests included total protein (TP), albumin (Alb), globulin (Glo), aspartate aminotransferase (AST), alanine transaminase (ALT), alkaline phosphatase (ALP), direct bilirubin (D.Bili), total bilirubin (T.Bili), serum iron (SI), total iron bounding capacity (TIBC), Albumin globulin ratioA/G ratio), and complete blood count (CBC). Results: Injection of 740Mbq99mTc-MIBI caused a significant increase in serum levels of AST (p= 0.001), ALT (p= 0.001), SI (p= 0.030), TIBC (p= 0.003) and A/G Ratio (p= 0.020). However, following radiotracer injection, a significant decrease was noted in the serum levels of TP (p= 0.002), Alb (p= 0.014), Glo(p= 0.002), ALP (p= 0.001), D.Bili (p= 0.003) and T.Bili (p= 0.000). Conclusion: Due to increased usage of MPI, our data highlights the importance of monitoring the clinical and paraclinical effects of the procedure on vital organs and physiological pathways to reduce their adverse effects

Authors and Affiliations

M. S. Alavi, M. A. Okhovat, M. Atefi, F. Khajeh Rahimi, S. Mortazavi

Keywords

Related Articles

An Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors

Introduction: Automatic and accurate arterial input function (AIF) selection has an essential role for quantification of cerebral perfusion hemodynamic parameters using dynamic susceptibility contrast magnetic resonance...

Monte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator

Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to im...

Combined Effect of Iodine Contrast Media, Cisplatin and External Beam Radiotherapy on Anaplastic Thyroid Cancer Cells

Introduction: The current study investigated the combination of high Z atoms (iodine-, platinium-based drugs) with using low energy irradiation (120kvp) in Anaplastic Thyroid cancer cells. Material and Methods: For this...

Comparative Analysis of Neural Network Training Methods in Real-time Radiotherapy

Background: The motions of body and tumor in some regions such as chest during radiotherapy treatments are one of the major concerns protecting normal tissues against high doses. By using real-time radiotherapy techniq...

Dynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback

Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic mul...

Download PDF file
  • EP ID EP453800
  • DOI -
  • Views 138
  • Downloads 0

How To Cite

M. S. Alavi, M. A. Okhovat, M. Atefi, F. Khajeh Rahimi, S. Mortazavi (2018). Evaluation of Blood Parameters Alteration Following Low-dose Radiation Induced by Myocardial Perfusion Imaging. Journal of Biomedical Physics and Engineering, 8(2), 179-184. https://europub.co.uk/articles/-A-453800