Abstract

The success of the implementations of a radiotherapy treatment planning system is determined by the ability of the dose calculation algorithms to reproduce the algorithm input data, and in most cases the agreement was found within ±2%. Varian linear accelerator DMX, TPS Eclipse (version 10.33) is used and absolute dosimetry and relative dosimetry system (PTW, Freiburg, Germany) and 2D array were also used. The Calculation of Analytical Anisotropic Algorithm (AAA) is more accurate than the Pencil beam Algorithm (PBC) in heterogeneity medium in comparison with practical measurement. The extent of the effort required to carry out a validation study of the complexity of that described here precludes its use as a routine component of TPS commissioning. Our realistic recommendation is that commissioning includes tests aimed at confirming that raw beam data have been entered correctly and that the operation of the system is understood. Finally, the study tell us that the observed deviations between TPS calculated using Eclipse version 10.33 and measured dose in the present of heterogeneous medium are well within the tolerance levels and the study also show that the use of Eclipse (version 10.33) TPS, AAA algorithm records significant improvement than the previous TPS versions especially in the present of low density inhomogeneity.

Authors and Affiliations

G. S. Hassan, Saleh A. Mohamed, Khaled M. Elshahat

Keywords

Related Articles

Signal-to-Noise Ratio importance in Apparent Diffusion Coefficient measurements using Diffusion-Weighted Echo-Planar-Imaging scans

Purpose: To define experimental grounds for Apparent Diffusion Coefficient (ADC) measurements using Spin-Echo Diffusion-Weighted Echo-Planar (SE-DW-EPI) sequences, as a function of Signal-to-Noise Ratio (SNR). Methods:...

Study on MHD Cylindrical Couette Flow and Rheological Properties of Some Magnetic Suspensions

The study of magnetic suspensions (MS) and magnetic field effects on their rheological properties is of evident practical importance due to its ability to orient and change their physical properties, especially their vis...

Conserved Quantities for the General Linear Heat Equation

In this paper, conserved quantities are computed for a class of evolution equation by using the partial Noether approach [2]. The partial Lagrangian approach is applied to the considered equation, infinite many conservat...

Confirming the Signal Integrity in Transmission of Digital Signals on Microstrip Straight Circuits via the Eye Diagrams

Because of the high volume of processing, transmission, and information storage, electronic systems presently requires faster clock speeds tosynchronizethe integrated circuits. Presently the speeds on the connections of...

The Extreme Downflow in the Umbral Light Bridge of the sunspot

Sunspots are the most readily visible manifestations of the interaction of the solar magnetic field with the solar atmosphere and the most prominent tracers of solar magnetic activity. Results of the recent studies based...