Evaluation of Retention of Different Attachment System used in Implant Retained Overdenture

Journal Title: Journal of Advanced Medical and Dental Sciences Research - Year 2018, Vol 6, Issue 4

Abstract

Background: Dental implants are widely used nowadays. The most common problem associated with the management of edentulous patients is the severely resorbed mandibular ridge, especially in older age when adaptive capacities are reduced. The present study was conducted to evaluate retention of different attachment system used in implant retained overdenture. Materials & Methods: The present study was conducted in the department of Prosthodontics. It comprised of edentulous mandibular models which were made with heat cured polymethyl methacrylate resin. Acrylic resin mandibular overdentures were fabricated and provision was made to receive three different overdenture attachment systems, prefabricated ball/o ring attachment, Hader bar and clip attachment and locator implant overdenture attachment stud type. Each of the models were subjected to 100 pulls each to dislodge the overdenture from the acrylic model. Results: Group I comprised of prefabricated ball/o ring attachment, group II Hader bar and clip attachment and group III locator stud type implant overdenture attachment. In group I, mean force (N/cm) BT was 55.11 and AT was 50.24, in group II, BT was 72.26 and AT was 66.04, in group III, BT was 42.10 and AT was 36.01. The difference among BT and AT in all groups was significant (P< 0.01). Conclusion: Attachment may determine the success of implant supported overdenture. Ball O ring and Hader bar clip attachment proved to be better in terms of retention in compariosn to locator type of attachment.

Authors and Affiliations

Pranjali Dutt, Pooran Chand, Vidhi Srivastava, Balendra Pratap Singh

Keywords

Related Articles

ACUTE TRANSFUSION REACTIONS IN PATIENTS ADMITTED TO HOSPITAL- A CLINICAL STUDY

Background: Any unfavorable event occurring in a patient during or after transfusion of blood and blood components and for which no other reason is known as a transfusion reaction. Transfusion is a frequently administere...

Blood Pressure Response to Azilsartan in Hypertensive Patients

Background: Azilsartan is a novel angiotensin receptor blocker (ARB) being created for hypertension treatment. The primary point of this article is to assess the viability, wellbeing, and clinical part of azilsartan in h...

Probiotics in Periodontics: A Review

Probiotics are counterparts of antibiotic thus are free from concerns for developing resistance, further they are body's own resident flora hence are most easily adapted to host. With fast evolving technology and integra...

Guided Bone Regeneration Using a Platelet-Rich Fibrin Membrane and Sticky Bone Graft along with Implant placement in Maxillary Anterior region: A Case Report

The maxillary anterior region is considered to be the esthetic zone of human dentition. Missing teeth in this area leads to severely compromised aesthetics and function. Endosseous implants are a viable option for tre...

A STUDY OF PREVALENCE OF CANCER IN FEMALE SEX POPULATION IN REWA REGION (M.P. STATE)

The present study entitled was undertaken to evaluate the incidence and pattern of cancer in female population in Rewa region in Madhya Pradesh State. For this purpose, the records available in the Histopathology Section...

Download PDF file
  • EP ID EP542292
  • DOI -
  • Views 144
  • Downloads 0

How To Cite

Pranjali Dutt, Pooran Chand, Vidhi Srivastava, Balendra Pratap Singh (2018). Evaluation of Retention of Different Attachment System used in Implant Retained Overdenture. Journal of Advanced Medical and Dental Sciences Research, 6(4), 95-97. https://europub.co.uk/articles/-A-542292