Evaluation of Vickers Hardness the Bulk Fill Type Resins: In vitro study
Journal Title: Stomatos - Year 2018, Vol 24, Issue 47
Abstract
This study aimed to verify the superficial and deep Vickers hardness of two flow type composite resins. The samples were divided into two groups: a single increment composite resin group, Filtek Bulk Fill Flow and another for conventional composite resin, Filtek Z350 XT Flow. Thirty specimens were prepared, 15 for each group. For the statistical analysis of the results the Student’s T test was used, showing that the average hardness of the top bulk resin was 26.08, with a standard deviation of 2.04 and a hardness of 18.58 with standard deviation of 3.19 and for the Z350 resin the average hardness at the top was 43.15, with a standard deviation of 2.89 and at the bottom of 21.89, with a standard deviation of 4.51. Based on the results of this study, it can be concluded that the Filtek Z350 Flow Composite resin presented Vickers hardness superior to Filtek Bulk Flow resin, both in the superficial and deep part, but its correlation between superficial and deep was 51%, while the material of single increment obtained a better result in this correlation, 71%.
Authors and Affiliations
Gabriela Silveira Dalcin, Karen da Rosa Gallas, Éverton dos Santos Ribeiro
DIAGNOSTICANDO E ALERTANDO PARA AS ENFERMIDADES BUCAIS E CÉRVICO-VAGINAIS
Pouco se sabe hoje em dia sobre possíveis correlações entre doenças bucais e as doenças cérvico-vaginais. Pode-se afirmar, contudo, que existem doenças que atingem ambas as regiões do corpo humano. O presente estud...
Soft tissue profile changes in class II patients treated with first bicuspid extraction
Objective: To assess soft tissue changes in the lip area after orthodontic treatment with first bicuspid extraction in 20 Angle class II patients. Methods: A total of 40 profile cephalograms were digitized and measured:...
Unusual foraminal position in a mandibular molar
Knowledge of possible morphological variations of the root canal system is crucial to achieve endodontic success. The radiographic apex is traditionally used as a reference point for establishing the apical limit of root...
INFLUÊNCIA DO USO DO LASER DE ND:YAG NA RESISTÊNCIA DE UNIÃO DE MATERIAIS RESINOSOS À DENTINA.
O objetivo desse estudo foi avaliar a influência do laser Nd:YAG na resistência à microtração de diferentes materiais adesivos à dentina humana. Dezoito terceiros molares humanos foram divididos em 6 grupos. Grupo...
“In vitro” wear behavior of extracoronal precision attachments
The objective of this study was to evaluate the retentive ability and weight change of two extracoronal attachments after repeated insertion/removal cycles. Material and methods: Two extracoronal attachments were used, o...