Experimental Investigation of the Useful Use of Electricity in Thermoelectric Generators by Using Waste Flue Gas
Journal Title: Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji - Year 2014, Vol 2, Issue 4
Abstract
As wiring up the many thermoelectric generators in serial, voltage can be increased and wiring up the parallel the current can be increased. In this work, experiment set has occured with thermoelectric generators. The generator surface which is need to keep warm is heated by waste gases produced in stove pipe and cooled water is passed through the cold surface to keep cool. Electricty production has occured because of the temperature differences. During operation the changing of voltage range is observed between 5,11V and 8,69V. When the flowrate is 0,083 lt/s, the maximum performance has observed with 8,69V and 1,45A. Varying the cooling water flowrate in experiment, changing of electricty production has observed and the results has shown graphical.
Authors and Affiliations
Mehmet ÖZKAYMAK, Sahin BAŞ, Bahadır ACAR, Celil YAVUZ, Kurtulus BORAN, A. Samet TABAK, H. İbrahim VARİYENLİ, Ömer ASAL
Basic Heterogeneous Catalyst Design for the Production of Soybean Oil Methyl Esters
In this study, hydroxyapatite (HAP) was prepared by using the co-precipitation method and used as a catalyst support material. 25 % KOH loaded HAP catalyst was prepared by wet-impregnation method and basicity of synthesi...
Frequency and Temperature Dependence of Dielectric Parameters of Metal-Oxide-Semiconductor (MOS) Capacitor
In this study, the dielectric parameters of metal-oxide-semiconductor (MOS) capacitor with silicon nitride (Si3N4) interfacial oxide layer have been investigated. The admittance measurements (capacitance and conductance)...
Simplify Backup on Virtual Servers
Virtualization technologies are becoming increasingly common in recent years. One of the major problems in institutions and organizations using virtualization technology is backup virtualized servers. Looking at the expe...
Scale Effect of İntak-Entrance Profile On An Air-Entraining Vortex
Scale Effect of İntak-Entrance Profile On An Air-Entraining Vortex
The Effect of Organic Polymer Interfacial Layer Thickness and Series Resistance C-G/-V Characteristics in Al/PVA (Zn-doped)/p-Si (MPS) Structure
In this study, the electrical properties of polymer interfacial layer Al/p-Si (MPS) with thickness of 50 and 150 nm (Zn-doped PVA) were investigated in terms of frequency using the capacitance- conductance-voltage (C-G/...