EXTERNAL MAGNETIC FIELD OF URBAN TRANSFORMER SUBSTATIONS AND METHODS OF ITS NORMALIZATION

Abstract

Purpose. Research of external magnetic field of urban transformer substations and the methods it reduction to the standard level in the living quarters of nearby. Methodology. Experiment based on the actual values the measuring magnetic flux density of the alternating magnetic field. Theories of electromagnetic field on quasi-static formulation is basis of external magnetic field of urban transformer substations description. Results. We have made comprehensive experimental researches the magnetic field of a 50 Hz through model urban transformer substations on the external environment. For calculating the external magnetic field of transformer substations the mathematical model of multi-dipole is proposed. It practical uses for induction external magnetic field of calculating created in nearby built in house transformer substations power 715 kVA is proposed. Comparison of results calculation and experiment was conducted. Originality. We have established that magnetic flux density of the magnetic field does not exceed standard level in the living quarters of nearby (0.5 T) if quarters the location distances of more than 8 m from the transformer substation on the first time. Transformer substations in the built-in houses can create the dangerous to public health magnetic field which induction 1.5-7 T in neighboring living quarters. It exceeds the normative level in 3-14 times. Practical value. We have proposed normalization methods of the external magnetic field built-in transformer substations. Methods are based on improving construction transformer substations. And methods of external passive and active shielding are considered.

Authors and Affiliations

V. Yu. Rozov, D. Ye. Pelevin, K. D. Pielievina

Keywords

Related Articles

FUNCTIONAL CORRELATION OF PARAMETERS AND CRITERIA OF RATIONAL CHOICE FOR ELECTRIC DEVICE

The existing theoretical and experimental dependences between power, electromagnetic and mass-overall dimension parameters of electric device have been analyzed. The choice of the generalized linear size has been substan...

GENERATOR ON ARCADYEV-MARX SCHEME WITH PEAKING OF THE PULSE FRONT IN ITS CASCADES FOR FOOD DISINFECTING

Purpose. To obtain experimentally that the duration of the high-voltage pulse front is less than 1.5 nanoseconds on the load of a pulse voltage generator of less than 50 ohms in the form of more than two working chambers...

THE DIAGNOSTICS OF INDUCTION MOTORS ROTOR BAR BREAKS BASED ON THE ANALYSIS OF ELECTROMOTIVE FORCE IN THE STATOR WINDINGS

A method for diagnostics of the induction motor rotor bar breaks, based on the wavelet-analysis of the electromotive force induced in the stator windings in the rundown mode is developed. A method for decomposition of th...

STABILIZATION OF PARAMETERS OF ASYNCHRONOUS ELECTRIC DRIVE WITH VECTOR CONTROL

A problem of stabilization of parameters of the asynchronous electric drive vector control system is considered. Usually such systems have two control channels. The synthesis of stabilizing controllers is made for every...

FREQUENCY CONTROL IN ELECTRICAL SYSTEM MATHEMATICAL MODELING AND OPERATION CONTROL PROBLEMS

To improve the performance of primary data processing algorithms when determining frequency in problems of mathematical modeling and operation control of electrical systems, it is proposed to represent discrete instantan...

Download PDF file
  • EP ID EP293565
  • DOI 10.20998/2074-272X.2017.5.10
  • Views 120
  • Downloads 0

How To Cite

V. Yu. Rozov, D. Ye. Pelevin, K. D. Pielievina (2017). EXTERNAL MAGNETIC FIELD OF URBAN TRANSFORMER SUBSTATIONS AND METHODS OF ITS NORMALIZATION. Електротехніка і Електромеханіка, 0(5), 60-66. https://europub.co.uk/articles/-A-293565