Failure Analysis of Boiler Tubes at LPGCL (Khanote)

Abstract

Failure of boiler tubes in a thermal power plant is a very common phenomenon. So run the plant safely it is imperative for every plant owners to investigate the reason of failure and find out the remedies to prevent frequent plant shut downs. This paper, therefore, aims to provide the failure analysis report of boiler tubes at Lakhra Power Generation Company limited LPGCL (Khanote). The investigation is comprised on visual examination, fractography analysis, microstructural investigations and chemical analysis of the tube material. Optical microscope, Scanning electron microscope (SEM), X-Ray diffraction (XRD) and electron dispersion spectroscopy (EDS) techniques were used. Results indicated that the major cause of failure was localized short-term overheating of the tube due to improper material used for manufacturing of boiler tube. The fracture appearance is called fish mouth opening.

Authors and Affiliations

Ahmed Abdullatif

Keywords

Related Articles

Lighting Control of a Resisdential Building Using Hybrid Occypancy Sensor

The growing development and urbanization has made the alterations in the human life style and comfort requirement particularly in the offices and residential buildings. About 40-45% of world’s energy consumption is being...

Reactivity Feedback Effect on the Reactor Behaviour during SBLOCA in a 4-loop PWR Westinghouse Design

The reactivity coefficient is a very important parameter for safety and Stability of reactors operation. To provide the safety analysis of the reactor, the calculation of changes in reactivity caused by temperature is ne...

Semi-automatic Picture Book Generation based on Story Model and Agent-based Simulation

In the fields of artificial intelligence, automatic narrative generation has attracted considerable interest. Lots of studies on narrative generation have been reported such as novel, comic, and picture book. However, mo...

Efficiency Evaluation of Thailand Gross Domestic Product Using DEA

The goal of this research is to evaluate the efficiency of GDP in Thailand from the past years and provide suggestions for government and policy-makers on ways to manage inputs and improve outputs in the future while enh...

Efficiency Evaluation of The Agricultural Sector in Senegal Based on Suitable Combinations of Inputs, CCR, And BBC in DEA

With regards to the global competitive environment that becomes more and more intense due to local and foreign competitions resulting from international trade and foreign direct investments, the emphasis has been put on...

Download PDF file
  • EP ID EP647393
  • DOI -
  • Views 140
  • Downloads 0

How To Cite

Ahmed Abdullatif (2019). Failure Analysis of Boiler Tubes at LPGCL (Khanote). International Journal of Modern Research In Engineering & Management., 2(3), 1-5. https://europub.co.uk/articles/-A-647393