Features of Using the Regulatory Method "Thermal Calculation of Boiler Units" for Firetube Boilers
Journal Title: Вентиляція, освітлення та теплогазопостачання - Year 2018, Vol 27, Issue
Abstract
In recent years, the practice of using fire-tube and fire-fighting water-heating boilers in the replacement of service water heating boilers in boiler-houses has become commonplace in the district heating systems of the cities of Ukraine. In this case, fire-extinguishing boilers can be used both imported and domestic. Designing boiler houses with such boilers and especially their construction often requires a heat calculation boiler, either test or constructive, but there is a problem. The normative document "Heat Calculation of Boiler Units" operating in Ukraine does not contain any instructions on calculation of fire-tube and boiler boilers. He gives orders for the calculation of water heaters and steam boilers, in addition, only with a capacity of more than 75 t / h. These guidelines can not always be used directly, directly. For example, for fire-tube and fire-fired boilers, heat pipes with a wavy wall surface are used. Such a case is not provided in the Normative document. There are difficulties in determining the parameter M which takes into account the nature of the temperature distribution along the height of the flue pipe and depends on the relative location of the maximum flame temperature and some others. The presence of such problems necessitates the development of a special regulatory document with recommendations for the heat calculation of fire-fueled boiler boilers or an annex to the current normative document devoted to solving this problem. A description of the main problems that arise during the heat calculation of fire-tube and boiler boilers with the help of the normative document "Heat calculation of boiler units" in Ukraine is presented and the way of their solution is shown
Authors and Affiliations
P. Glamazdin, М. Kryvoruk, R. Schwarzenberger
Estimation of the Efficiency of Building Environment Using Influence of Several Parameters on People, Based on the Point Calculus
According to the law of optimum in ecology, each factor has a certain range (the optimum zone), in which a person feels comfort. If the factor values come out of this range, the body is depressed. When designing environm...
Influence оf the Design Features оf the Energy Pile оn іts Efficiency
An important area of energy conservation is the use of energy efficient heat supply systems. Such systems are systems with heat pumps to utilize the low-potential heat of the upper layers of the earth's crust. The urgent...
Possibilities for Reducing the Accident Rate of Centralized Hot Water Supply Networks by Water Deaeration
The analysis of the most typical causes of failures in the work of the central hot water supply systems. The most widespread methods that reduce accidents centralized domestic hot water systems.It can be used for design,...
Optimization of the Parameters of the Heat Network Under a Reduced Temperature Schedule
The economic and environmental problems of Ukraine lead to decrease the water temperature in heat supply systems. Increasing the cost of fuel made it inappropriate to schedule temperature 95/70. To switch to a lower temp...
Solid Fuel Boilers Equipped With Fire Chambers Using а "Fluidized Layer"
The article describes the design of a new combustion device using the fluidized bed technology for burning low-grade coals and unconventional fuels. The experience of the development and implementation of the practice of...