Features of Using the Regulatory Method "Thermal Calculation of Boiler Units" for Firetube Boilers

Abstract

In recent years, the practice of using fire-tube and fire-fighting water-heating boilers in the replacement of service water heating boilers in boiler-houses has become commonplace in the district heating systems of the cities of Ukraine. In this case, fire-extinguishing boilers can be used both imported and domestic. Designing boiler houses with such boilers and especially their construction often requires a heat calculation boiler, either test or constructive, but there is a problem. The normative document "Heat Calculation of Boiler Units" operating in Ukraine does not contain any instructions on calculation of fire-tube and boiler boilers. He gives orders for the calculation of water heaters and steam boilers, in addition, only with a capacity of more than 75 t / h. These guidelines can not always be used directly, directly. For example, for fire-tube and fire-fired boilers, heat pipes with a wavy wall surface are used. Such a case is not provided in the Normative document. There are difficulties in determining the parameter M which takes into account the nature of the temperature distribution along the height of the flue pipe and depends on the relative location of the maximum flame temperature and some others. The presence of such problems necessitates the development of a special regulatory document with recommendations for the heat calculation of fire-fueled boiler boilers or an annex to the current normative document devoted to solving this problem. A description of the main problems that arise during the heat calculation of fire-tube and boiler boilers with the help of the normative document "Heat calculation of boiler units" in Ukraine is presented and the way of their solution is shown

Authors and Affiliations

P. Glamazdin, М. Kryvoruk, R. Schwarzenberger

Keywords

Related Articles

Influence on the Environment of a Thermal Power Plant on Wood Waste

The possibility to increase the effectiveness of the solar radiation energy usage up to 30^40 percent was established. This result was achieved by heating the energy source with increased flow rate during the expanding o...

Types of Exergy in air conditioning systems and their definition

The results of the determination of the basic material and physical flows in air conditioning systems and their expressions in terms of exergy are given. The analytical dependence in a convenient form for engineering ca...

Calculations of Energetic and Exergetic Efficiency of Hot Water Systems

The paper shows the methodology and examples of calculations of energetic and exergetic efficiency of hot water systems. Conducted on the basis of the developed method of thermodynamic analysis the results of previous st...

Estimation of Energy Consumption of Ventilation and Air Conditioning Systems

Requirements for modern air conditioning systems must include a calculation of their power consumption for the entire summer. Manufacturer show characteristic SEER, which is an indicative value and does not reflect the a...

Comparison of Constructions of Heat Accumulators with a Solid Heat Storage Material and Combined HeatStorage Material

One of the thermal energy storage technologies during the warm season, its preservation and future use is to create seasonal heat accumulators. As a source of heat during the warm period of the year for charging seasonal...

Download PDF file
  • EP ID EP556026
  • DOI -
  • Views 66
  • Downloads 0

How To Cite

P. Glamazdin, М. Kryvoruk, R. Schwarzenberger (2018). Features of Using the Regulatory Method "Thermal Calculation of Boiler Units" for Firetube Boilers. Вентиляція, освітлення та теплогазопостачання, 27(), 18-22. https://europub.co.uk/articles/-A-556026