Field Effects on Multiple Particle Contamination And Breakdown Voltage Inside Gas Insulated Bus Duct.

Abstract

The metallic particle contamination in the Gas-Insulated Systems (GIS), plays a key role for the occurrence of Partial Discharge (PD), which causes the failure of insulation in the GIS. This paper presents the study of field effects on multiple particle contamination and breakdown voltage initiated by metallic particles inside a gas insulated bus duct filled with SF6 gas. In this paper, A single Phase Gas Insulated Bus duct with inner diameter conductor of 55mm and diameter of enclosure 150 mm is considered. Three metallic Particles of size of 10 mm in length and 0.25 mm radius, 10 mm length and 0.15 mm radius and 7 mm and 0.25 radii are considered to be present in the GIB. the Finite Elements Method is used to evaluate the electric field distributions on and around the metallic particles at different positions of the particles like when resting on the enclosure and particles floating inside the gap. Electric field intensity in the GIS are studied for both single particle and multiple particles at a time. The breakdown voltages for both single and multiple particle contamination are determined. The effect of gas pressure on the breakdown voltages also studied.

Authors and Affiliations

Ranuva Nageswara Rao, Dr. S. S Tulasiram

Keywords

Related Articles

Monitoring of the Sulfur and Nano Silver in Water by Method of Laser Spectroscopy

We developed new automatic method that combines the method of forced lumines-cence and stimulated Brillouin scattering (SBS). We used the method for the pathogens monitoring in water supply system earlier. We have resear...

Rebound Property in Low Velocity Impact of Two Equivalent Balls

The present study focuses on an impact phenomenon of two spheres and its rebound property. The collision of two spheres is a fundamental problem with impact phenomenon. The coefficient of restitution characterizes the pr...

Wind Speed Forecasting: A Review

Climate change causes serious impacts on the atmospheric such as violent storms, floods, fires, cyclones, acid rain and prolonged droughts. Nations of the whole world have been striving to achieve a sustainable developme...

Ontology study in service-oriented architecture

Service-oriented architecture and shared services are widely studied in the literature of information technology.However, there is no way to manage shared services in their use.This article provides an ontology map for s...

Carbon Credits and Carbon Trading: Impact on Climate Change

The temperature of earth has seen a phenomenal jump in last decade or so. Most of this change is attributed to the rise in level of carbon dioxide due to burning of fossil fuel. The developed nations of the world are maj...

Download PDF file
  • EP ID EP392056
  • DOI 10.9790/9622-0708046671.
  • Views 106
  • Downloads 0

How To Cite

Ranuva Nageswara Rao, Dr. S. S Tulasiram (2017). Field Effects on Multiple Particle Contamination And Breakdown Voltage Inside Gas Insulated Bus Duct.. International Journal of engineering Research and Applications, 7(8), 66-71. https://europub.co.uk/articles/-A-392056