First assessment the analytical quality specification in Clinical Chemistry laboratory, using Sigma scale and EQA/PT in Iran: a pilot study

Journal Title: World Journal of Pharmaceutical Sciences - Year 2017, Vol 5, Issue 8

Abstract

Background: To assess the analytical performance of quality trough external quality assesses and internal quality program data on sigma scale. Method and material: Imprecision was determined from the cumulative Levey-jenning SD over the 6 month, bias was calculated from the external quality records, Finally, analytical sigma metric estimates were calculated for each Analytes by the following equation: sigma metric: (TEa – Bias)/CV. All function and statistical analysis were done in our Private laboratories. Result: The sigma value >6 was observed for most analytes. Some of analytes have poor sigma metric <3 such as Creatinine and ALP in normal level and Calcium in pathologic level. Glucose, Urea, Uric Acid, Calcium, Phosphorous, total bilirubin, in normal levels and Urea, Creatinine, total and direct bilirubin in pathologic level have intermediate sigma metric 4-6. Conclusion: Chemistry tests are not commodities. Quality varies significantly from manufactures to manufactures and method to method. The sigma-assessment from multiple EQA/IQC programs provides more insight into the performance of methods and quality. Laboratory seeking optimal quality program would do well to consult this data as part of their decision-working process.

Authors and Affiliations

Reza Pahlavan Gharehbaba

Keywords

Related Articles

Evaluation of analgesic activity of methanol extract from the Spondias pinnata

This Present study was surpassed to investigate the methanolic fruit extracts of Spondias pinnata for analgesic activities in rats using Acetic acid induced writhing test & Formalin induced licking test. S. pinnata is a...

Comparative study of rheumatoid factor with anti - CCP antibodies by ELISA method in the diagnosis of rheumatoid arthritis

Rheumatoid Arthritis is a chronic inflammatory disease of unknown aetiology marked by a symmetric peripheral polyarthritis. It is the most common form of chronic inflammatory arthritis and often results in joint damage a...

Anti-obesity and hypolipidemic activity of siddha drugs: A review

Obesity has reached epidemic proportions globally with more than one million adults overweight and at least 300 million of them are clinically obese. It pose a major risk for diseases like type 2 diabetes mellitus, hyper...

Comparative study of Bee Propolis from different Geographical location

Cancer is now one of the leading causes of death in developing countries, killing more people globally each year than any other. By 2020 there are expected to be 15 million new cases of cancer every year globally, 70% of...

Antibiotic susceptibility of Streptococcus pyogenes and Staphylococcus aureus isolated from Pharyngitis and Tonsillitis patients in Nasiriyah City, Iraq

The present study aimed to isolation and identification and antibiotic susceptibility test for Streptococcus pyogenes and Staphylococcus aureus bacteria isolated from Pharyngitis and Tonsillitis patients. 276 swabs were...

Download PDF file
  • EP ID EP330331
  • DOI -
  • Views 128
  • Downloads 0

How To Cite

Reza Pahlavan Gharehbaba (2017). First assessment the analytical quality specification in Clinical Chemistry laboratory, using Sigma scale and EQA/PT in Iran: a pilot study. World Journal of Pharmaceutical Sciences, 5(8), 165-170. https://europub.co.uk/articles/-A-330331