FUNCTIONAL AND RADIOLOGICAL OUTCOME OF TIBIAL PLATEAU FRACTURES (SCHATZKER TYPE 5 & 6) TREATED WITH ILIZAROV CIRCULAR EXTERNAL RING FIXATOR

Journal Title: Journal of Evidence Based Medicine and Healthcare - Year 2016, Vol 3, Issue 1

Abstract

INTRODUCTION Fractures of the tibial plateau are the result of high energy trauma. Because of the nature of the trauma and the relative high frequency of soft tissue injuries, the rate of complications is high. Complications include joint stiffness, compartment syndrome, malunion, skin loss, osteomyelitis, and possible amputation. The Ilizarov external fixator helps in minimizing these complications by allowing early mobilization and weight bearing, minimal soft tissue injury and blood loss along with a stable fixation MATERIAL AND METHODS In our prospective study of 20 patients which included adults with open/closed Schatzker type 5 and 6 tibial plateau fractures, we studied the outcome following surgery with Ilizarov external fixation using the modified Hohl and Luck criteria which includes functional (extensor lag, valgus or varus instability, knee range of movement, walking distance and pain) and radiological parameters (valgus/varus deformity, depression of articular surface and osteoarthritis). RESULTS All patients (n = 20) started weight bearing the day after the surgery. Functionally, 55% (n=11) had a excellent result, 40% (n=8) had a good result. 75% (n=15) had an excellent result radiologically. 3 patients out of 20 had a pin tract infection and one patient had an early implant removal due to non-compliance. CONCLUSION Treatment of open/ closed tibial plateau fractures with Ilizarov circular external ring fixator has proven to be advantageous in terms of early weight bearing and minimal soft tissue compromise. Excellent Radiological outcome is not necessarily associated with similar functional outcome.

Authors and Affiliations

Sheshagiri A, Arunodhaya Siddartha, Siddalingamurthy Siddalingamurthy, Purushotam Sastry, Mruthyunjaya Mruthyunjaya, Anubhav Verma

Keywords

Related Articles

HAEMATOLOGICAL PARAMETERS AND VITAMIN B12 LEVELS IN TYPE II DIABETIC PATIENTS ON METFORMIN- A PROSPECTIVE CASE CONTROL STUDY

BACKGROUND Metformin is the cornerstone medication in the management of type 2 diabetes mellitus (T2DM) with estimates that it is routinely prescribed to 120 million type 2 diabetes patients around the world. Preceding s...

A STUDY OF SURGICAL SITE INFECTIONS IN ABDOMINAL SURGERIES

BACKGROUND Infections that occur in the wound created by an invasive surgical procedure are generally referred to as surgical site infections (SSIs). Abdominal surgical site infections are among the most common infectiou...

A PROSPECTIVE, RANDOMIZED CONTROL STUDY EVALUATING THE POSTOPERATIVE ANALGESIA USING RECTAL DICLOFENAC IN PATIENTS UNDERGOING ELECTIVE LAPAROSCOPIC CHOLECYSTECTOMY SURGERIES

BACKGROUND: To assess the efficacy of rectal diclofenac suppository in patients undergoing elective laparoscopic cholecystectomy surgeries in management of postoperative pain, in reduction of intra operative opioid requi...

COMPARISON BETWEEN ASPIRATION AND NON-ASPIRATION TECHNIQUE IN FINE NEEDLE CYTOLOGY OF LYMPH NODE

BACKGROUND Fine needle aspiration cytology is a simple, easy and safe procedure. It has been used for the diagnosis of superficial palpable lesions successfully. Deep-seated lesions have also been sampled by fine needle...

COMPARATIVE STUDY OF EFFICACY OF DIPSI AND O’SULLIVAN’S METHOD OF SCREENING FOR GDM

OBJECTIVE: 1. To compare screening and diagnosis of gestational diabetes mellitus by Diabetes In Pregnancy Study Group of India (DIPSI) recommended 75g oral glucose challenge test with O’Sullivan’s 50 g oral glucose chal...

Download PDF file
  • EP ID EP231552
  • DOI 10.18410/jebmh/2016/7
  • Views 51
  • Downloads 0

How To Cite

Sheshagiri A, Arunodhaya Siddartha, Siddalingamurthy Siddalingamurthy, Purushotam Sastry, Mruthyunjaya Mruthyunjaya, Anubhav Verma (2016). FUNCTIONAL AND RADIOLOGICAL OUTCOME OF TIBIAL PLATEAU FRACTURES (SCHATZKER TYPE 5 & 6) TREATED WITH ILIZAROV CIRCULAR EXTERNAL RING FIXATOR. Journal of Evidence Based Medicine and Healthcare, 3(1), 30-35. https://europub.co.uk/articles/-A-231552