Generation of Good Quality Direct Input Data for Mathematical Models of Pulsatile Flow of Blood in Animal CVS

Journal Title: International Journal of Engineering and Science Invention - Year 2018, Vol 7, Issue 5

Abstract

The aim of the paper is to investigate a good quality direct input data for mathematical models of pulsatile flow of blood in animal cardio-vascular system (CVS). It is first shown that the input data used in the literature of pulsatile flow of blood is either too ideal or incorrect. Then using Fourier series and numerical integration methods, four in-vivo experimental data (pressure gradient profiles for pulsatile flow of blood) for four different locations of animal CVS are converted into a mathematical form that could be readily used as input data for mathematical models. A comparison of experimental and mathematical profiles shows a good agreement between them (error about 10%). A computer program is developed using this method and is presented through appendix.

Authors and Affiliations

Anand Bansal, P. R. Sharma, P. Chaturani

Keywords

Related Articles

Analysis of Principles of Determining Hydrological Characteristics for the Design Cross-Section of the Hydropower Plant

The article reviews the problems associated with the principles of determining hydrological characteristics for the cross-section of water intake structures of Hydropower Plant (HPP) projects in Georgia. The case study o...

Performance of Mechanical Plastic Mulch Laying Practices: A Review

The plastic mulch applications in the agriculture are based on type, source and degradability. There is increasing interest in the use of plastic mulching for fruit and vegetable crops in the Agriculture field. Globally...

Solving Exponential Equations: Learning from the Students We Teach

The purpose of this paper is to share with the mathematics community what I discovered from analyzingone of myGrade 11 students’ approach to solving exponential equations of the form a a k x p x q     , where a and k...

Resilient sanitation for settlements affected by water scarcity: A case study of Manabí, Ecuador

Sanitation in Manabí is considered an unmet basic need, which despite the efforts of the various levels of Government to cover it, does not seem to have given significant advances. Conventional technology to give coverag...

Internet of things (IoT): – Communication, characteristics, results

The purpose of this paper is explainthe matter of Internet of Things, what are the advantages from its use, what type of characteristics it has, the technological trends and the practical implementation - Connecting to A...

Download PDF file
  • EP ID EP396963
  • DOI -
  • Views 73
  • Downloads 0

How To Cite

Anand Bansal, P. R. Sharma, P. Chaturani (2018). Generation of Good Quality Direct Input Data for Mathematical Models of Pulsatile Flow of Blood in Animal CVS. International Journal of Engineering and Science Invention, 7(5), 1-6. https://europub.co.uk/articles/-A-396963