Abstract

Purpose: The aim of the work was roughness investigation of the surface of developed oesophageal prosthesis before and after texturing, to estimate its influence on future application of prosthesis. Design/methodology/approach: Linear, mechanical contact-measurement method and, for verification, optical profile measurement in confocal microscope were used in the work. Findings: The roughness investigation of the surface of developed oesophageal prosthesis before and after texturing was necessary to estimate its influence on future application of prosthesis. Research limitations/implications: The results of investigations of prosthesis of the human oesophagus internal and external surface roughness will be used to design the manufacturing technology and to manufacture given prosthesis. Originality/value: Investigation of geometrical structure of internal and external surface of internal oesophageal prosthesis is the part of the research project realized by authors, that will result in cognitive, constructional and technological effects, but first of all, it will enable the real help very sick people.

Authors and Affiliations

Agnieszka J. Nowak, Leszek A. Dobrzański

Keywords

Related Articles

Application of polymer impression masses for the obtaining of dental working models for the stereolithographic 3D printing

Purpose: The aim of the work is to execute measurements of digital dental models taken by scanning prosthetic impressions using the engineering CAD software and finding dimensional differences and scale factor for precis...

Transparent conductive nanocomposite layers with polymer matrix and silver nanowires reinforcement

Purpose: The article deals with one of the completely new groups of composite inorganic nanostructured materials used in the form of surface layers, characterised by unique properties, such as transparency over 84.4% in...

The effect of deformation degree on the microstructure of the 6060 aluminium alloy

Purpose: All results obtained in the present study allowed to analyse the changes in the microstructure and texture of the commercial 6060 aluminium alloy, after deformation process by severe plastic deformation. There w...

The analysis of buckling and post buckling in the compressed composite columns

Purpose: The aim of the study was to analyse the work of a thin-walled C-shaped profile, made of a carbon-epoxy composite, which was subjected to unified axial compression. Design/methodology/approach: The scope of the s...

Download PDF file
  • EP ID EP188952
  • DOI -
  • Views 125
  • Downloads 0

How To Cite

Agnieszka J. Nowak, Leszek A. Dobrzański (2017). Geometrical structure investigation of the surface of internal oesophagus prosthesis. Archives of Materials Science and Engineering, 2(83), 79-85. https://europub.co.uk/articles/-A-188952