HEAT TESTS OF POWER CABLES WITH XLPE INSULATION AT DIRECT VOLTAGES UP TO 110 KV

Abstract

In this paper, experiment for determining the temperature difference between the elements of cable and in the open air is considered. The formation of a three cables laid in a plane with different spacing between adjacent cables. Tests to heat of cables for XLPE-polyethylene are used as a solid dielectric insulation. The line to XLPE-cables in group running horizontally, provided that the cables are of equal diameter and emit equal losses. It is limited to the following: the air flow around the cables may be necessary restricted by proximity to next cables. When single-core cables are installed in parallel the load current may not share equally between the parallel cables. This is because a significant proportion of the impedance of large conductors is due to self reactance and mutual reactance. Hence the spacing and relative location of each cable will have an effect on the current sharing. Calculation for each cable configuration is necessary. Possibility of using for determining the thermal properties of XLPE-cables a sheath applied over the cable surface with coefficient convection heat transfer between cable surface and the air region about it of equal zero. The work is devoted to creation of a method for calculation of the current rating of high-voltage cables in conditions function.

Authors and Affiliations

T. Yu. Antonets, Yu. M. Vepryk, L. A. Shchebeniuk

Keywords

Related Articles

CAST-FILM POLYMER COMPOSITION DOSING SYSTEM DRIVE CONTROL

Object parameters providing uniformity of polymer composition outflow from the spinneret to the substrate are analyzed. An approach to drive controller construction for a dosing system comprising a lag element is conside...

APPLICATION OF VYSHNEGRADKY'S DIAGRAMS FOR TRANSIENT ANALYSIS IN ELECTRIC DISCHARGE INSTALLATIONS WITH STOCHASTIC LOAD

Purpose. To analyze the transient processes in the discharge circuit of reservoir capacitor of electric discharge installations at a change in the circuit configuration during the discharge as well as to determine the ap...

COMPARATIVE ANALYSIS OF ACTIVE POWER LOSSES OF INDUCTION MOTORS WITH CYLINDRICAL AND AXIAL AIR GAPS

Purpose. To find the analytical expressions of determining the optimum geometric dimensions by criteria of the losses minimum of axial field squirrel-cage induction motors and to compare traditional and axial field motor...

INCREASING CONTROL’S EFFICIENCY FOR THE SHIP’S TWO-MASS ELECTRIC DRIVE

Purpose. For shipboard lifting and transporting machinery (LTM) with AC thyristor electric drives (ED) the problem of minimizing sway through the formation of the special law to change the principle of ED control over th...

COMPARATIVE ANALYSIS OF ELECTRICAL AND THERMAL CONTROL OF THE LINING STATE OF INDUCTION APPARATUS OF COPPER WIRE MANUFACTURE

Aim. This article is intended to develop a technique for monitoring the lining state of induction channel furnaces for melting oxygen-free copper by monitoring changes in the distribution of thermal fields in their linin...

Download PDF file
  • EP ID EP299154
  • DOI 10.20998/2074-272X.2015.6.07
  • Views 79
  • Downloads 0

How To Cite

T. Yu. Antonets, Yu. M. Vepryk, L. A. Shchebeniuk (2015). HEAT TESTS OF POWER CABLES WITH XLPE INSULATION AT DIRECT VOLTAGES UP TO 110 KV. Електротехніка і Електромеханіка, 0(6), 43-46. https://europub.co.uk/articles/-A-299154