IMMEDIATE RESULTS OF BALLOON VALVULOPLASTY FOR PULMONARY STENOSIS DEPENDING ON THE TYPE OF STENOSIS

Journal Title: International scientific journal Science and Innovation - Year 2024, Vol 3, Issue 8

Abstract

Objective: To analyze the immediate outcomes of balloon valvuloplasty (BV) for pulmonary stenosis (PS) based on the type of narrowing. Materials and Methods: The study included 180 patients with PA and RVOT stenoses who underwent BV at the State Institution "Republican Specialized Scientific and Practical Medical Center of Surgery named after Academician V. Vakhidov" from 2010 to 2022. Patients with isolated PA valve stenosis were included. Exclusion criteria were critical PA stenosis, pregnancy, and complex congenital heart disease. Patients were categorized by initial right ventricular (RV) systolic pressure: ≤100 mm Hg (43.3%), 101-150 mm Hg (30.0%), 151-200 mm Hg (16.7%), and >200 mm Hg (10.0%). To determine the dependence of the results on the type of PA obstruction, patients were divided into the following groups: valvular PS (n=144), valvular-subvalvular PS (n=27), valvular-supravalvular PS (n=9). Results: In isolated valvular PS (n=144), RV systolic pressure decreased from 118.2±14.7 mm Hg to 55.1±6.3 mm Hg, PA pressure increased from 22.9±2.7 mm Hg to 28.5±2.9 mm Hg, and the RV-PA pressure gradient dropped from 94.0±10.4 mm Hg to 26.3±3.1 mm Hg. Good results were seen in 79.2%, satisfactory - in 13.9%, and unsatisfactory - in 6.9% of patients. For combined valvular-subvalvular PS (n=22), RV pressure decreased from 148.6±16.8 mm Hg to 82.4±7.2 mm Hg, PA pressure increased from 21.3±2.5 mm Hg to 27.0±3.6 mm Hg, and the gradient fell from 129.1±14.3 mm Hg to 56.7±6.2 mm Hg. Good outcomes were achieved in 44.4%, satisfactory - in 33.3%, and unsatisfactory - in 22.2%. In valvular-supravalvular PS (n=9), RV pressure decreased from 130.4±2.5 mm Hg to 55.3±1.9 mm Hg, PA pressure increased to 28.5±1.5 mm Hg, and the gradient dropped from 113.6±1.8 mm Hg to 21.3±1.1 mm Hg. Good results were seen in 77.8% of patients. Conclusion: BV effectively treats isolated valvular PS, significantly improving clinical and hemodynamic outcomes. The procedure is also beneficial for combined stenoses but with higher residual gradients. For valvular-supravalvular stenosis, BV shows high efficacy despite limited data.

Authors and Affiliations

Umarov M. M.

Keywords

Related Articles

THEORETICAL ASPECTS OF PSYCHOLOGICAL AND PEDAGOGICAL DIAGNOSTIC METHODS IN PRACTICE

This problem can be solved only by students who have studied the discipline “Psychological and Pedagogical Diagnostics”. Psychological and pedagogical diagnostics, being one of the most important disciplines directly rel...

INFLUENCE OF NATURAL FACTORS IN THE PROCESS OF STUDENTS' PHYSICAL EDUCATION AND SPORTS ACTIVITIES

This article discusses environmental factors affecting physical education and sports, scientific views, negative effects of mankind on ecology and environment. The need to pay more attention to the relationship between e...

COORDINATION OF THE PEDAGOGICAL PROCESS AND THE CHOICE OF THE RIGHT TEACHING METHODS - AN IMPORTANT ASPECT OF THE EFFECTIVENESS OF EDUCATION AND UPBRINGING

This article describes the theoretical and practical problems facing the education system, the importance of coordinating the pedagogical process and the right choice of teaching methods in overcoming them to ensure th...

CHECKING TECHNOLOGY OF VOCABULARY BANK IN PRE-SCHOOL CHILDREN WITH UNDEVELOPED SPEECH

This article presents the methodology and results of checking vocabulary in preschool children with underdeveloped speech

EXPRESSION OF INTELLECT IN SPEECH ACTIVITY

Speech is a tool of thought. The article analyzes speech and its role in human activity. The direct dependence of speech on the activity of the mind, as well as thinking, is expressed. It also expresses the uniqueness of...

Download PDF file
  • EP ID EP744837
  • DOI 10.5281/zenodo.13636827
  • Views 12
  • Downloads 0

How To Cite

Umarov M. M. (2024). IMMEDIATE RESULTS OF BALLOON VALVULOPLASTY FOR PULMONARY STENOSIS DEPENDING ON THE TYPE OF STENOSIS. International scientific journal Science and Innovation, 3(8), -. https://europub.co.uk/articles/-A-744837