IMPACT OF REAL AND REACTIVE POWER CONTROLLABILITY OF STATCOM ON TRANSMISSION LINE PROTECTION

Abstract

Static synchronous Compensator (STATCOM) is a shunt connected Voltage Source Converter (VSC) based FACTS controller which is useful in improving the voltage regulation. VSC based FACTS controllers facilitate connection of energy storage devices like battery, fuel cell, Super Magnetic Energy Storage(SMES) etc. at the DC bus. Addition of energy storage device results in better real and reactive power flow control, transient stability enhancement and power oscillation damping. However, FACTS controllers with energy storage device in the line poses new challenges for the line protection device. Operating region of STATCOM with energy storage device (STATCOM – ES) encompasses all the four quadrants in P – Q plane. Impedance contribution by STATCOM operating in any of these four quadrants can modify apparent impedance seen by distance relay and hence needs to be investigated thoroughly. Main aim of this paper is to analyze the impact of emulated conductance and susceptance by four quadrant operation of STATCOM on the performance of distance relay in a hybrid compensated system. A novel control strategy to dynamically modify the reference for real power exchange by STATCOM is proposed to avoid damage to the STATCOM during fault. Possibilities of distance relay under reach and over reach due to operation of STATCOM - ES in various operating modes and impact of fault resistance on the relay performance is discussed

Authors and Affiliations

H. V. GURURAJA RAO, NAGESH PRABHU, R. C. MALA

Keywords

Related Articles

STUDY AND ANALYSIS OF PROTECTION SCHEME OF DIGITAL SUBSTATION USING IEC61850-9-2 PROCESS BUS TECHNOLOGY

Substations are a fundamental part in electrical energy transmission and distribution. The role of a substation is to transfer and transform electrical energy by stepping up or down the voltage. To do this, high voltag...

MODELING, ANALYSIS AND ANFIS CONTROL FOR DTC-SVM OF INDUCTION MOTOR OF AN ELECTRIC VEHICLE USING ELECTRICAL DIFFERENTIAL

This paper presents modeling, analysis and simulation of DTC-SVM of Induction motor which suits for application of electric vehicle (EV) with two independent rear wheel drive. DTC-SVM endure from torque ripples and poo...

SENSORLESS VECTOR CONTROL OF INDUCTION MOTORUSING MODEL REFERENCE ADAPTIVE SYSTEM

The implementation and performance evaluation of sensorless vector control of three-phase induction motor is carried out in this paper which uses Model Reference Adaptive System (MRAS) technique for the estimation of m...

REACTIVE POWER AND AC VOLTAGE CONTROL OF LCC HVDC WITH SFCL SYSTEM WITH CONTROLLABLE CAPACITORS

This paper implements the AC voltage control of HVDC using superconducting fault current limiter (SFCL) in AC voltage control of LCC HVDC using controllable capacitors. Also to analyze the behavior of a Voltage Source...

FRACTIONAL ORDER PID CONTROLLER FOR AGC LOOP OF A TWO-AREA SOLAR-THERMAL DEREGULATED POWER SYSTEM WITH RFB AND IPFC UNIT

This paper presents the Fractional Order Proportional-Integral-Derivative (FOPID) controller for Automatic Generation Control (AGC) of an interconnected twoarea solar-thermal deregulated power system. In this investigat...

Download PDF file
  • EP ID EP46593
  • DOI 10.34218/IJEET.10.3.2019.004
  • Views 157
  • Downloads 0

How To Cite

H. V. GURURAJA RAO, NAGESH PRABHU, R. C. MALA (2019). IMPACT OF REAL AND REACTIVE POWER CONTROLLABILITY OF STATCOM ON TRANSMISSION LINE PROTECTION. International Journal of Electrical Engineering & Technology (IJEET), 10(3), -. https://europub.co.uk/articles/-A-46593