Implementation of shunt active power filter with comparative study of SPWM and SVPWM technique for reduction of THD

Abstract

This paper presents a comparative study of two different PWM techniques, i.e. the sinusoidal pulse width modulation (SPWM) technique, and the space vector pulse width modulation (SVPWM) technique for three phase H bridge inverter with shunt active power filter (SAPF) to reducing the total harmonic distortion in a non linear loads. In conventional diode clamped inverter required balancing circuit and extra diodes for clamping. In proposing H bridge inverter no extra diodes and balancing circuit are required and reduce the complexity and cost. The performance of SPWM and SVPWM technique is analysed by using MATLAB / Simulink software.

Authors and Affiliations

Ms. Priyanka S. Salunkhe, Mrs. Shruti Gaur

Keywords

Related Articles

Simulation of Hairpin Monopole Antenna using High Frequency Structural Simulator Software

A revolution in science of electronics and communication has emerged in the last few decades, with the potential to create a paradigm shift in thinking about simulation theories . The paper throws some light on the utili...

Interpretation of Distance Metric Learningover Image Retrieval System

The process of Learning distance function over different substances is called as Metric learning. In several of data mining processes like clustering, nearest neighbors etc. is very important problem that relies on dista...

Pattern recognition of infrared images and pseudo-color image processing : Forest fire in himalaya

Human growth in diversified fields has impacted atmosphere a lot. Every time Nature wants to balance and to tune with the universal effects. Resistance of human imbalances all of it’s efforts, which results into disaster...

The Evaluation of Consultant Supervisors Performance on Road Construction Project in East Borneo

The Road constructions in East Borneo, which is developed in 2015, is expected to produce road infrastructure that could be done as the plan and its regardless from the role of the consultant supervisors performance whic...

Lever Operated Sprayer using Rotary Pump

The Mechanism comprises lever operated knapsack sprayer provided with rotary pump, which is placed outside the tank and have separate pressure chamber. Rotary pump is operated by lever through gear arrangement. When the...

Download PDF file
  • EP ID EP392174
  • DOI 10.9790/9622-0709034247.
  • Views 116
  • Downloads 0

How To Cite

Ms. Priyanka S. Salunkhe, Mrs. Shruti Gaur (2017). Implementation of shunt active power filter with comparative study of SPWM and SVPWM technique for reduction of THD. International Journal of engineering Research and Applications, 7(9), 47-47. https://europub.co.uk/articles/-A-392174