Improvement of main inverter of combined power system with renewable energy sources

Abstract

Considered a single-phase current controlled voltage source bridge inverter for the converter unit with renewable energy sources. In parallel work with AC network the inverter is provides a power factor equal to one, regardless of the type of load and the direction of energy transfer. In autonomous mode, when the AC network is disconnected, inverter provides the energy transfer to the load. Proposed solutions with using a two-level and three-level hysteresis current controller with adjustable setting trigger of controller. This allows for the formation of a unipolar voltage inverter and to reduce the number of switching of transistors with limiting the frequency switching. When operating on AC power inverter current reference is formed in accordance with the load current and the power that is generated from renewable sources. In the autonomous mode, the instantaneous value of the load voltage is formed by a proportional-integral voltage controller that generates a reference to the hysteresis current controller. The current regulator is provides to limit the inverter current for transient regimes. The inverter is connected to AC power and load through the reactor. In the autonomous mode, the capacitor is connected parallel to the load. The inverter control system, which implements the proposed solutions have been developed. Simulation has executed for a system which includes a source AC with active and inductive impedance of power line, inverter with its control system and combined load. The load is an active-inductive, and includes a rectifier with an output capacitor filter. The simulation results confirm the effectiveness of solutions that are offered.

Authors and Affiliations

A. A. Shavelkin, S. M. Kozhemyakin

Keywords

Related Articles

The main relationships for calculations in two-circuits resonant amplifier of the electric power

Based on a Tesla transformer and an idealized circuit of two consecutive reactive active inductively coupled circuits with zero active resistance of the secondary circuit, a scheme of a resonant electric power amplifier...

Application eddy-current frequency balance for monitoring of material properties by unprofitable converters

It is shown that electromagnetic converters based on the use of eddy-current frequency balance, allow almost completely to get rid of the influence (effect) of air gaps between the converter and a controllable detail. Th...

Requirements for contact materials of switching devices

It is proposed to move from use in the construction of high-current electrical apparatus of copper alloys as electrical contact materials to powder materials. An analysis of the composition of the powder material is pres...

Structure and kinematic scheme of medium voltage vacuum contactors

The structure and kinematic schemes of vacuum contactors are considered. The review of design is presented and the operation principle of medium voltage vacuum contactors by foreign manufacturers is considered.

Simulation of control axial flux permanent magnet generator

This article gives analysis and comparison of control system and stabilization external characteristic of axial flux generator. A technical solution is proposed that allow to control and stabilize external characteristic...

Download PDF file
  • EP ID EP408699
  • DOI -
  • Views 104
  • Downloads 0

How To Cite

A. A. Shavelkin, S. M. Kozhemyakin (2016). Improvement of main inverter of combined power system with renewable energy sources. Вісник Національного технічного університету "ХПІ". Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика, 32(1204), 42-47. https://europub.co.uk/articles/-A-408699