Improvement of main inverter of combined power system with renewable energy sources

Abstract

Considered a single-phase current controlled voltage source bridge inverter for the converter unit with renewable energy sources. In parallel work with AC network the inverter is provides a power factor equal to one, regardless of the type of load and the direction of energy transfer. In autonomous mode, when the AC network is disconnected, inverter provides the energy transfer to the load. Proposed solutions with using a two-level and three-level hysteresis current controller with adjustable setting trigger of controller. This allows for the formation of a unipolar voltage inverter and to reduce the number of switching of transistors with limiting the frequency switching. When operating on AC power inverter current reference is formed in accordance with the load current and the power that is generated from renewable sources. In the autonomous mode, the instantaneous value of the load voltage is formed by a proportional-integral voltage controller that generates a reference to the hysteresis current controller. The current regulator is provides to limit the inverter current for transient regimes. The inverter is connected to AC power and load through the reactor. In the autonomous mode, the capacitor is connected parallel to the load. The inverter control system, which implements the proposed solutions have been developed. Simulation has executed for a system which includes a source AC with active and inductive impedance of power line, inverter with its control system and combined load. The load is an active-inductive, and includes a rectifier with an output capacitor filter. The simulation results confirm the effectiveness of solutions that are offered.

Authors and Affiliations

A. A. Shavelkin, S. M. Kozhemyakin

Keywords

Related Articles

Analysis of the influence of the magnetic permeability of the steel reinforced concrete structures on the level of the geomagnetic field inside premises

It is shown that the use in the construction of standard reinforcing bars leads to a dangerous weakening of the geomagnetic field on the premises. The requirements for the magnetic permeability "weakly magnetic" structur...

Power transformer station 330/110 kV power lines in the presence of harmonics

Disabling or damage to overhead power lines of high and extra-high voltage (power lines) caused by various reasons, among which is not the last place is occupied by both natural factors - the effects of lightning and bir...

Investigations of transients in the device of forced control of the vacuum contactor monostable electromagnet

A review of systems of forced control with buster and holding windings is carried out. It is found that there is a large number of various systems of forced control of electromagnets. It has been established that in the...

The use of microcontrollers in studies of electric vehicles

The structural and circuit diagrams stands automated process control system studies (ACS TPI) electric devices based on MCUs MK1816VE51 and MSP430 and the algorithm of its work.

Requirements for contact materials of switching devices

It is proposed to move from use in the construction of high-current electrical apparatus of copper alloys as electrical contact materials to powder materials. An analysis of the composition of the powder material is pres...

Download PDF file
  • EP ID EP408699
  • DOI -
  • Views 121
  • Downloads 0

How To Cite

A. A. Shavelkin, S. M. Kozhemyakin (2016). Improvement of main inverter of combined power system with renewable energy sources. Вісник Національного технічного університету "ХПІ". Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика, 32(1204), 42-47. https://europub.co.uk/articles/-A-408699