Indirect Current Control Algorithm Implementation and Validation, for Active Filtering Using Constant Switching Frequency Hysteresis Controllers
Journal Title: ANALELE UNIVERSITATII DIN CRAIOVA - Seria Inginerie electrica - Year 2018, Vol 42, Issue 0
Abstract
The aim of this paper is the implementation and the experimental validation of a constant switching frequency hysteresis current controller as a part of an active filtering system control algorithm, based on the indirect current control. The classical choices in the literature are the hysteresis current controller and the PI controller both with their corresponding advantages and disadvantages. A solution which achieves the advantages of both classical hysteresis and PI controllers is the constant switching frequency hysteresis current controller. This controller can be obtained by combining the hysteresis comparators with the PWM suboptimal modulator. The performances of the active filtering system based on the indirect current control and the proposed controller are compared with the corresponding performances obtained by the same system implemented with the well documented PI current controller. The regulator implementation and performance comparative study were accomplished on a comprehensive experimental active filtering system based on the dSpace DS1103 prototyping board.
Authors and Affiliations
Mihaita Linca, Vlad Constantin Suru, Cristina Alexandra Preda
Coupled Magneto-Thermal Model for an Encapsulated Busbars System Using QuickField
In this paper, we propose an approach for the magnetic and thermal modeling of an encapsulated busbars system, in three-phase execution, for high voltage using QuickField software. The paper proposes a numerical...
COMPUTATIONAL ANALYSIS OF HYDRODYNAMIC EFFECTS IN HYDRAULIC FLOW TURBINES (PART 1)
Research and elaboration of the systems for conversion of renewable energy sources (RSE) as a research objective present great interest and importance. Hydraulic energy currently is one of the most used, cheap and clean...
CPC - Based Reactive Compensation of Linear Loads Supplied with Asymmetrical Nonsinusoidal Voltage
The paper presents a method of calculation of LC parameters of reactive balancing compensators of linear time-invariant (LTI) loads supplied with a nonsinusoidal and asymmetrical voltage. The method is based on the Cur-r...
The Online Temperature Control
In this paper is presented the hardware and software design of a remote controlled system which can have multiple destinations. In particularly, this system is used to create an online thermostat using a microcont...
Theoretical and Practical Aspects Regarding Radiated Emission Testing in Semi-Anechoic Chambers
This paper presents some theoretical and practical aspects on measurements of radiated emission from a Portable computer. The used Standards are presented and discussed. The measurements were carried out in a Semi-Anecho...