Influence of dead band and speed of the regulator on frequency stabilization process in power system with powerful wind power plants and battery energy storage systems
Journal Title: Проблеми загальної енергетики - Year 2018, Vol 0, Issue 3
Abstract
This paper describes the process of controlling the frequency and power in a system with a powerful wind power plant and a battery energy storage system, which can be used in combination to compensate changes in power and maintain frequency at a given level with different values of the dead band and regulator speed. The study of process of regulating the frequency and power in a power system was carried out using mathematical modeling of the aggregated power system, which included, in addition to the wind power plant and battery energy storage system, thermal, nuclear and hydroelectric power plants, and taking into account losses and specified limits. The analysis of simulation results showed that the battery energy storage system, involved into the frequency and power control loop, reliably maintains the frequency in the system with its deviation not exceeding half the width of regulator's dead band. It is established that the accuracy of frequency control in the system depends on the controller speed. A threshold value of controller speed was found. It was shown that, with decrease in regulator speed below given threshold value, the frequency deviations go beyond the dead band. It was also determined that reducing the regulator response speed leads to a decrease in the accuracy of frequency control in proportion to the increase in the dead band.
Authors and Affiliations
Oleksandr Zgurovets
Revision of the possibilities of the models of equilibrium prices and outputs in the theory of intersectoral balance
Based on the performed analysis of numerous publications containing the models of equilibrium prices and outputs in the theory of intersectoral balance, we have proved that the use of transposed matrices of direct cost i...
Benchmarking assessment of development options for low-capacity centralized heating systems
The greatest challenge in switching the centralized heating systems in population centres to local fuel and energy resources (FER) is that the local level administrations are lacking clear objectives, milestones and crit...
The determination of maximum capacities of solar power plants in IPS of Ukraine
The maximum value of the solar power plant (SPP) in the power system depends on the performance reserve and regulating capacity of the automatic frequency and power control (AFPC) system. It is believed that the regulato...
Increase in the economic and ecological parameters of power plants by means of utilization of the ash-slag waste of boilers
In the EU, USA, and a series of developed countries of the world, the ash and slag of power plants are considered as technogenic raw materials for many branches of industry. The systems of pneumatic ash and slag removal...
System overview of the methods used to study power units with variable process parameters, and practical aspects of modeling
The article discusses specifics of technical and economic studies concerning variable or undetermined duty, operating, financial and economic parameters. Based on certain classification indicators (the availability of st...