Influence of sample hemolysis on ELISA test results in blood screening laboratory

Journal Title: Chinese Journal of Blood Transfusion - Year 2024, Vol 37, Issue 4

Abstract

Objective To analyze the effect of sample hemolysis on ELISA test results in blood screening laboratory, so as to determine the acceptable tolerance of hemolysis specific to laboratory test items and detection system, and provide reference for the formulation of tolerance standard of sample hemolysis. Methods Negative and weakly positive (S/CO was about 2) samples with different hemolysis degrees were tested by several commonly used domestic reagents for HBsAg, HIV Ag/Ab, anti-HCV and anti-TP, respectively. The effects of various degrees of hemolysis on the test results of negative and weakly positive samples for each item were analyzed. Results 1) Hemolysis had no effect on the test results (reactive/non-reactive) of negative and weakly positive samples for HBsAg, anti-HCV and anti-TP ELISA items; 2) Hemolysis affected the test results (reactive/non-reactive) of negative and weakly positive samples for HIV Ag/Ab ELISA item. A tolerance of Hb 2 g/L was taken as the acceptable hemolysis degree for HIV Ag/Ab ELISA item. Conclusion In this study, the acceptable tolerance of hemolytic samples for corresponding test items and detection system in our laboratory were determined. The influence of hemolysis on ELISA test result is related to the reagent, equipment, environment and other factors, therefore the acceptable tolerance of hemolysis should be determined scientifically and reasonably based on the specific evaluation of each laboratory.

Authors and Affiliations

Qianqian QIN, Hongwei GE, Jing ZHANG, Zifu ZHAO, Chan LENG, Rui WANG

Keywords

Related Articles

Preliminary exploration on operation process for autologous ozonized blood transfusion

Autologous ozonized blood transfusion(AOBT) is a therapy of re-transfusion of 100-200 mL of autologous blood after shaking and agitation with appropriate amount of oxygen-ozone in vitro. The oxidation of blood through th...

Ultrasound guided autologous platelet-rich plasma injection for the treatment of common peroneal nerve compression syndrome: a case report

Objective To observe the clinical efficacy of ultrasound-guided autologous platelet- rich plasma (PRP) injection for the treatment of common peroneal nerve compression syndrome, and to provide reference for the treatment...

Identification of B(A) subtype and analysis of bood transfusion strategiaes

Objective To investigate the serology and genotype identification method of B (A) subtype patients. Methods Test tube method (serology) was used to confirm the clinically difficult ABO blood group samples of 3 patients w...

Prognostic analysis of perioperative zero red blood cell transfusion in patients with acute Stanford type A

Objective To investigate the correlation between perioperative zero red blood cell(RBC) transfusion and the prognosis of patients with acute Stanford type A aortic dissection. Methods A retrospective analysis was made on...

Effects of autologous platelet-rich plasma combined with negative pressure wound therapy for chronic refractory wounds: a Meta-analysis

Objective To systematically evaluate the therapeutic efficacy of autologous platelet-rich plasma combined with negative pressure wound therapy on chronic refractory wounds, and to provide reference for clinical treatment...

Download PDF file
  • EP ID EP738798
  • DOI 10.13303/j.cjbt.issn.1004-549x.2024.04.008
  • Views 28
  • Downloads 0

How To Cite

Qianqian QIN, Hongwei GE, Jing ZHANG, Zifu ZHAO, Chan LENG, Rui WANG (2024). Influence of sample hemolysis on ELISA test results in blood screening laboratory. Chinese Journal of Blood Transfusion, 37(4), -. https://europub.co.uk/articles/-A-738798