Influence of the alloy composition on determining the millesimal fineness of gold by X-ray fluorescent and assay analysis

Abstract

<p>The conducted studies revealed the influence of the methods of cupellation and the XFA on the accuracy of determining the millesimal fineness in the system of the assay control. The effect of the alloy composition of jewelry alloys on determining millesimal fineness was established. In particular, it was experimentally proved that nickel in combination with zinc as an integrated alloying component substantially changes the cupellation process of gold alloys. This leads to deviation of the millesimal fineness of a gold alloy, determined by cupellation compared with the X-ray fluorescent analysis (XFA) towards a decrease ranging from 0.10 to 0.15 %.</p><p>The research of gold alloys with the content of nickel with the help of the XFA revealed microalloying by modifiers and actively acting deoxidizing agents (indium, palladium, platinum, etc.). It was established that modifiers are used both separately and in complex, but they do not make a significant impact on determining the millesimal fineness.</p><p>A number of systemic and random errors in techniques, which affect the results of determining and are related to the technique of performing preparatory operations, as well as analyses operation, were detected. Based on the obtained results, the permanent temperature mode was developed and the procedure of the process of cupellation of gold alloys with the content of nickel was improved with a view to further improvement and metrological certification of the procedure.</p>It was proved that the use of the XFA method for control of millesimal fineness and the content of the component composition of modern gold-based pieces of jewelry and museum values (antiques) is possible not only as the method of screening. The method can replace the touchstone (with obvious advantages), and be an alternative to cupellation. Application of the XFA for current control of millesimal fineness and the content of an alloy of jewelry pieces is advisable to increase up to 30 % (against 2 % in accordance with the current legislation). Its use will make it possible to increase the number of analyzed samples without worsening the trading presentation of the jewelry pieces of a customer

Authors and Affiliations

Tatyana Artyukh, Inna Hryhorenko, Alla Ternova, Svitlana Yaheliuk, Mihai Cernavca

Keywords

Related Articles

Development of a technology of structuring group expert judgments under various types of uncertainty

<p>The study considers the problem of structuring expert judgments formed under conditions of uncertainty of different nature and in presence of conflicting expert evidence. The method of aggregating group expert judgmen...

A procedure of studying stationary motions of a rotor with attached bodies (auto-balancer) using a flat model as an example

<p>The energy method of studying rotor dynamics has been modernized. The method is applicable to the rotors mounted on isotropic elastic-viscous supports when bodies are attached to the rotors and relative motion of thes...

Modeling of energy efficient solutions regarding the heating system and the facade heat insulation in the implementation of thermomodernization

<p>We substantiated design and construction-technological solutions for increasing the energy efficiency of thermomodernizable buildings and structures based on the conducted calculation-and-experimental and numerical st...

Aerodynamics of the turbulent flow around a multi­element airfoil in cruse configuration and in takeoff and landing configuration

<p>Numerical modeling of multi-element airfoil's aerodynamics employs the Reynolds averaged Navier-Stokes equations of incompressible environment, which are related via a single-parametric differential turbulence model b...

Design of parallel link mobile robot manipulator mechanisms based on function-oriented element base

<p>To create effective mobile robot manipulators, a function-oriented element base is proposed. Element base selection is based on the analysis of schematics of mobile robot manipulators. It is substantiated that the eff...

Download PDF file
  • EP ID EP528233
  • DOI 10.15587/1729-4061.2018.142730
  • Views 64
  • Downloads 0

How To Cite

Tatyana Artyukh, Inna Hryhorenko, Alla Ternova, Svitlana Yaheliuk, Mihai Cernavca (2018). Influence of the alloy composition on determining the millesimal fineness of gold by X-ray fluorescent and assay analysis. Восточно-Европейский журнал передовых технологий, 5(12), 6-18. https://europub.co.uk/articles/-A-528233