Interference of heart and transcutaneous oxygen monitoring in the measurement of bioelectrical impedance analysis in preterm newborns

Journal Title: Jornal de Pediatria - Year 2016, Vol 92, Issue 5

Abstract

Objective To verify if the connection of electrodes for heart and transcutaneous oxygen monitoring interfere with the measurement of electrical bioimpedance in preterm newborns. Methods This was a prospective, blinded, controlled, cross-sectional, crossover study that assessed and compared paired measures of resistance (R) and reactance (Xc) by BIA, obtained with and without monitoring wires attached to the preterm newborn. The measurements were performed in immediate sequence, after randomization to the presence or absence of electrodes. The sample size calculated was 114 measurements or tests with monitoring wires and 114 without monitoring wires, considering for a difference between the averages of 0.1 ohms, with an alpha error of 10% and beta error of 20%, with significance <0.05. Results No differences were observed between the R (677.37±196.07 vs. 677.46±194.86) and Xc (31.15±9.36 vs. 31.01±9.56) values obtained with and without monitoring wires, respectively, with good correlation between them (R: 0.997 and Xc: 0.968). Conclusion The presence of heart and/or transcutaneous oxygen monitoring wires connected to the preterm newborn did not affect the values of R or Xc measured by BIA, allowing them to be carried out in this population without risks.

Authors and Affiliations

Viviane Comym

Keywords

Related Articles

Breastfeeding duration and associated factors between 1960 and 2000

Objective To describe a historical series on the median duration of breastfeeding in a population of mothers whose children were born from the 1960s onwards, identifying factors associated with the interruption of breast...

Reference curves of the body fat index in adolescents and their association with anthropometric variables

Objectives To develop reference curves for the body fat index (BFI) in the pediatric population, in adolescents from the city of São Paulo, Brazil, and verify their association with body mass index and body fat percentag...

Influence of maternity leave on exclusive breastfeeding

Objectives To describe the profile of women with children aged under 4 months living in the Brazilian state capitals and in the Federal District according to their working status and to analyze the influence of maternity...

Infection with multidrug-resistant gram-negative bacteria in a pediatric oncology intensive care unit: risk factors and outcomes

Objective This study aimed at evaluating the predictors and outcomes associated with multidrug-resistant gram-negative bacterial (MDR-GNB) infections in an oncology pediatric intensive care unit (PICU). Methods Data wer...

Nutritional evaluation of children with chronic cholestatic disease

Objective To evaluate the nutritional status of children with persistent cholestasis and to compare the anthropometric indices between children with and without liver cirrhosis and children with and without jaundice. Me...

Download PDF file
  • EP ID EP512297
  • DOI 10.1016/j.jped.2016.01.009
  • Views 40
  • Downloads 0

How To Cite

Viviane Comym (2016). Interference of heart and transcutaneous oxygen monitoring in the measurement of bioelectrical impedance analysis in preterm newborns. Jornal de Pediatria, 92(5), 528-531. https://europub.co.uk/articles/-A-512297