INTERLABORATORY COMPARISON OF THE ELECTROMAGNETIC EMISSION MEASUREMENTS USING FAR AND GTEM TEST SITES UP TO 1 GHz
Journal Title: Proceedings of Electrotechnical Institute Prace Instytutu Elektrotechniki - Year 2014, Vol 61, Issue 267
Abstract
Electromagnetic emission limiting is one of the basic requirements in the European Directive 2014/30/EU (EMC Directive). Manufacturers often use alternative methods of measurements to make preliminary verification of emission. This paper presents and analyzes problem with comparison between measurements in different test sites: FAR (Fully Anechoic Room) and GTEM (Gigahertz Transverse Electromagnetic cell). FAR is assumed as the reference and GTEM as the alternative method. There are results of measurements carried out in Electrotechnical Institute Gdansk Branch (FAR) and Satel Sp. z o.o. company (GTEM). It is concluded that the results from these two test sites cannot be easily compared or scaled but the measurement in the GTEM was more restrictive for the tested device in wider frequency range.<br/><br/>
Authors and Affiliations
Stanisław Galla, Tomasz Lisewski, Wojciech Władziński
WYZNACZANIE STRAT I SPRAWNOŚCI TRÓJFAZOWYCH SILNIKÓW INDUKCYJNYCH KLATKOWYCH – NOWE WYMAGANIA NORM
W pracy przedstawiono metodę wyznaczania strat i sprawności silników indukcyjnych klatkowych według normy polskiej PN-EN 60034-2-1:2008. Podano wymagania dotyczące dokładności przyrządów, procedurę przeprowadzania badań...
LASER-INDUCED BREAKDOWN SPECTROSCOPY FOR PAINTING LAYERS RESEARCH ON THE DOOR OF THE KING’S CHINESE ROOM AT THE WILANOW PALACE MUSEUM
Results of the research of the European lacquerware layers deposited on the door of the King’s Chinese Room at the Wilanów Palace Museum are presented. Laser-Induced Breakdown Spectroscopy and the optical microscopy were...
ANALIZA SILNIKÓW KLATKOWYCH PROGRAMEM POLOWYM
Analizowano wyniki pomiarów dwóch silników klatkowych (2 i 4 biegunowego) oraz wyniki obliczeń analitycznych wykonanych dwoma różnymi programami (jeden program projektowy wykonany w NME oparty o model obwodowy silnika, d...
AN ACCURACY OF DETERMINING THE PARAMETERS OF THE HIP JOINTS OF CHILDREN BASED ON IMAGES OBTAINED BY USING X-RAY
This article presents aspects of assessing of the accuracy of determining of the parameters of the child hip joints for measurements of selected anatomical angles and indices. A developed computer program that uses image...
PREDICTION OF UNUSUAL DYNAMICAL BEHAVIOR OF PERMANENT-MAGNET SYNCHRONOUS MOTOR
This paper presents mathematical equations describing the unusual dynamical behavior of a permanent-magnet synchronous motor. The dynamical behavior of the proposed machine has been defined both in real three phase co-or...