Intra and Inter-Observer Variability of Transformation Zone Assessment in Colposcopy: A Qualitative and Quantitative Study
Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 1
Abstract
Introduction: Colposcopy is an important tool in the diagnosis of cervical precancer and early cancer. The assessment of women with abnormal cytology and selection of those who require further therapy or follow up depends on the colposcopic assessment of the Transformation Zone (TZ). Identification of the TZ is thus an important part of this examination. Intra and inter-observer variability is known to be relatively high in the colposcopic interpretation of abnormal features. However, there are hardly any studies on the observer variability in the assessment of the type of TZ. Aim: The present study was conducted with the aim to compare the intra and inter-observer variability of the TZ type classification and the Squamo-Columnar Junction (SCJ) visibility and to quantitatively measure the intra and inter-observer correlations of tracing of the TZ contours. Materials and Methods: Colposcopy images were obtained for a total of 170 cases. They were reviewed by three colposcopists independently. The colposcopists classified the TZ type and also marked the SCJ contours on the images. Each observer independently reviewed the cases on two different instances (few weeks apart) and the result was compiled for intra-observer variation. The intra and inter observer variability on the TZ type was compared using Cohen’s Kappa. This was followed by a quantitative measurement of TZ observation variability using Hausdorff distance. Results: The inter-observer agreement for the TZ type classification was moderate (Kappa= 0.53 to 0.66). The Intra-observer agreement was moderate to strong (0.60 to 0.86). Conclusion: Colposcopic in vivo examination increases the variability in the identification of the TZ when compared to the analysis of recorded images. The disagreement in the TZ type was mostly in categories Type 2 vs Type 3 followed by Type 1 vs Type 2. A computerized quantification method can be used for quality control and training purpose in colposcopy.
Authors and Affiliations
Elizabeth Vallikad, Premalatha Thekkada Siddartha, Kiran Abhijit Kulkarni, Celine Firtion, Payal Keswarpu, Pallavi Vajinepalli, Sarif Naik, Lovi Gupta
Clinicopathological Spectrum of Nodal Peripheral T-cell Lymphomas: Observations and Inferences of Half a Decade
ABSTRACT Introduction: Nodal Peripheral T-Cell Lymphomas (NPTCL) are a rare and heterogeneous group of lymphomas seen to occur more often in Asian, including South Indian population. They have an overall poor prognosis....
Effect of Dry-Needling Induced Muscle Soreness (DIMS) on the Severity of Pain Post Deep Trigger Point Needling
Introduction: Dry-Needling (DN) induced muscle soreness is a common adverse event that takes place in almost majority of patients who received deep dry needling treatment. The effect of soreness on clinical outcomes has...
Radiographically Detectable Dystrophic Calcinosis of the Cheek: A Case Report and Literature Review
ABSTRACT Dystrophic calcinosis is a condition wherein calcium is deposited in degenerated tissues, often associated with trauma, infection, or inflammation, in the absence of a systemic mineral imbalance. It commonly occ...
Up the Duff With Non-Hodgkin’s Lymphoma: The Traumas and the Dilemmas
Lymphoma is fourth most frequent malignancy diagnosed prenatally (~1:6000 cases), with Hodgkin’s Lymphoma (HL) forming the major chunk. However, in recent times, there has been an increase in occurrence of Non-Hodgkin’s...
The Risk of Facial Fillings Aesthetic Procedures: A Case Report
ABSTRACT Facial cosmetic procedures are on increasing demand, for plastic surgeons and dental professionals now-a-days. New techniques applied for the renewal offacial contours have become the first treatment option befo...