Intra- and Inter-operator Reproducibility Analysis of Automated Cloud-based Carotid Intima Media Thickness Ultrasound Measurement
Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 2
Abstract
ABSTRACT Introduction: Manual carotid intima media thickness (cIMT) measurements are tedious and prone to errors. Further, these measurements are subject to intra and inter-observer variability. Several studies affirm the requirement for an automated system for cIMT computation, but they still suffer from low reproducibility and lack standardisation towards clinical trials. The novelty of this study is to demonstrate the intra and inter-operator reproducibility for a cloud-based automated cIMT measurement system. Aim: To demonstrate the reproducibility analysis and validation of cloud-based automated cIMT measurement systems. Materials and Methods: The reproducibility analysis was performed by two operators at three separate times (six auto readings: 1a, 1b, 1c, 2a, 2b, 2c). For validation of cloud-based cIMT measurement system, we compared the automated readings against the manual readings by the expert. The expert readings were provided by two observers who manually traced the LI/MA borders at two separate times (four manual readings: 1a, 1b, 2a, 2b). Further, we also performed the variability analysis of the manual readings. Results: The mean Correlation Coefficients (CC) for six intra and nine inter-operator reproducibilities between the auto readings pairs were: 0.99 (p<0.001) and 0.96 (p<0.001), respectively. The mean CCs for two intra and four inter-observer variabilities between the manual readings pairs were 0.94 (p<0.001) and 0.95 (p<0.001), respectively. The accuracy computed between the mean of the six auto readings against each of the four manual readings were: 96.88%, 97.26%, 99.04%, and 98.95%, respectively. While keeping the threshold at 0.9 mm, the ROC using eight combinations give a mean AUC of 0.97±0.01. Conclusion: The proposed cloud-based automated cIMT measurement software system showed high reproducibility. The system can be adapted for routine or clinical (pharmaceutical) trial modes.
Authors and Affiliations
Luca Saba, Sumit K Banchhor, Tadashi Araki, Harman S Suri, Narendra D Londhe, John R Laird, Klaudija Viskovic, Jasjit S Suri
Pyrexia of Unknown Origin: A Perplexing Case
ABSTRACT Pyrexia of Unknown Origin (PUO) is a common diagnostic dilemma in the medical wards. We present the case of a 64-year-old man who had presented with fever, fatigue, dry cough and bloody diarrhea. Over the next f...
Gender Linked Metric Analysis of Portal Vein: A Sonographic Appraisal
Introduction: Portal hypertension is one of the most mystifying and disconcerting abdominal ailment. Ultrasonography (USG) is an effective diagnostic tool for its prompt management. Knowledge of normal calibre of portal...
Excision of Masson’s Haemangioma Following Suspected Liposarcoma on Imaging
ABSTRACT Lipomas are commonly seen in general practice. Lipomas of large size should be investigated for the possibility of a soft tissue sarcoma. Intravascular papillary endothelial hyperplasia (Masson’s haemangioma) is...
Management of Chronic Blink Related Microtrauma in Stevens-Johnson Syndrome with Oral Mucous Membrane Graft Transplantation: A Novel Approach
A 26-year-old male was referred with sequel of Stevens-Johnson Syndrome (SJS) in form of bilateral severe keratinisation of lid margin and Symbhlepharon involving in particular forniceal region. At the time of presentati...
A Comparative Study to Identify the Effects of Transcutaneous Electrical Nerve Stimulation Combined with Sensorimotor Task Oriented Training to Improve the Hand Function in Hemiplegic Cerebral Palsy Children
ABSTRACT Introduction: Impaired hand function is one of the major growing concerns for hemiplegic cerebral palsy children. Poor hand function is more often due to either individual or combination of the motor and sensory...