INTRAOBSERVER AND INTEROBSERVER RELIABILITY OF THE RADIOLOGICAL DIAGNOSIS CRITERIA OF SCHEURMANN’S DISEASE

Journal Title: Journal of Turkish Spinal Surgery - Year 2018, Vol 29, Issue 2

Abstract

Objective: Scheuermann’s disease is diagnosed radiologically. Radiological measurements play role both in diagnosis of the disease and in the planning of the treatment. In this study, the evaluation of the intra-observer and inter-observer reliability of the radiological measurements used in Scheuermann disease was aimed. Material and Methods: Ten patients with Scheuermann disease diagnosed by both practitioners were evaluated. The wedging angle on the most wedged vertebra and the kyphosis angle of the patients were measured by two different observers two times for 3 weeks apart. Results: The correlation coefficients for intra-observer reliability in Scheuermann’s disease ranged % 84 - % 92.7 in the measurement of kyphosis angle and it was ranged % 70,8 - % 90,5 in the measurement of the wedging angle. The correlation coefficients for interobserver reliability were detected 87.9 % and 89.7 % for kyphosis angle measurements; and 82% and 68.1% for the measurement of wedging angle. Conclusion: Radiological measurements used in Scheuermann’s disease have high intra-observer and interobserver reliability.

Authors and Affiliations

Mehmet ERKILINÇ, Alkan BAYRAK, Mustafa Cevdet AVKAN

Keywords

Related Articles

MANAGEMENT OF SPİNE TUMORS

From March 1988 to Aprİl 1994 9 patients with spinal turno rai lesions have been operated İn our clinic. 6 malignant (3 metastatic) and 3 benign tumors were localized on thoracal (5), lumbar (3 metastatic) and 3 benign t...

DOES ANTER10R SPSNAL İNSTRUMENT ROTATİON CAUSE RETROLISTHESÎS OF THE LOWER İNSTRUMENTED VERTEBRA?

Background: Dwyer and Zietke anterior instruments are wide!y used in spine deformities. Derotatİon of the scolioiic spine is possible wüh the special device of the Zielke instrument However, new rigid systems don't ne...

ASSESSMENT OF SPINAL IMPLANTS UNDER CYCLIC LOADING

An experimental technique is developed to study the transfer of load through spinal Instruments when subjected to cyclic loading. İn this study two series of tests are conducted on in vitro calf spines comprising of thre...

RECENT ADVENCES IN MEDICAL TREATMENT OF OSTEOPOROSIS

Osteoporosis is the most common bone disease, associated with low bone mineral density (BMD) and pathological fractures which lead to significant morbidity. It is defined clinically by a BMD of 2.5 standard deviations or...

MR IMAGING OF DIASTEMATOMYELIA: Report of 41 Cases

Diastematomyleia is a form of occult spinal dysraphism that could go undetected urıtil adulthood with nonspe-cific complaints and neurologic-orthopedic symptoms. 41 patients (31 females, 10 males) with ages betvveen 1-mo...

Download PDF file
  • EP ID EP676997
  • DOI -
  • Views 121
  • Downloads 0

How To Cite

Mehmet ERKILINÇ, Alkan BAYRAK, Mustafa Cevdet AVKAN (2018). INTRAOBSERVER AND INTEROBSERVER RELIABILITY OF THE RADIOLOGICAL DIAGNOSIS CRITERIA OF SCHEURMANN’S DISEASE. Journal of Turkish Spinal Surgery, 29(2), -. https://europub.co.uk/articles/-A-676997