Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach
Journal Title: Journal of Biomedical Physics and Engineering - Year 2019, Vol 9, Issue 3
Abstract
Background: Metal prostheses in patients affect the radiotherapy dose distribution. Metal prostheses with high density and atomic number cause major changes in scattering and attenuation of radiation. The present study aims to assess the impact of metal knee prosthesis with various dimensions and materials on radiotherapy dose distribution. Material and Methods: In this research, the Varian Linac and water phantom were simulated using the MCNPX code. Dose distribution of photon beam in a water phantom, with and without the presence of knee prostheses made of cobalt-chromium-molybdenum alloy, steel, titanium, and titanium alloy used in men and women was investigated using the Monte Carlo simulation. Results: The prosthesis led to an increase in dose in comparison with cases that there was used no prosthesis. According to values of the depth dose percentage, the maximum dose increase was found to be 6.8%, 6.1%, 4%, and 4.29%, and dose reduction 41.18%, 40.66%, 37.76%, and 37.51% for prosthetics with men’s knee dimensions made of cobalt-chromium-molybdenum alloy, steel, titanium alloy, and titanium, respectively. Above all, does increasing to 6.4%, 5.9%, 3.8%, and 3.94% and doses reducing to 40.87%, 40.36%, 36.94%, and 36.69 were observed in prosthetics for women. The highest amount of dose reduction for men’s prostheses made of mentioned materials was found to be 48.75%, 47.7%, 45%, and 45.8%, respectively. In addition, it was 46.36%, 45.8%, 43.8%, and 43.95% for women’s prostheses, respectively. Conclusion: Material will have a significant impact if a part of the knee bone places behind the prosthesis. According to the obtained values, it is recommended to utilize prostheses made of titanium and titanium alloys for knee arthroplasty. The prosthesis can either increase or decrease dose in tumor or lead to increase dose at organs at risk. Citation: Bayatiani M. R, Seif F, Hamidi S, Bagheri S. Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach. J Biomed Phys Eng. 2019;9(3):345-354. https://doi.org/10.31661/jbpe.v0i0.1047.
Authors and Affiliations
F. Seif, M. R. Bayatiani, S. Hamidi
Enhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound
Background Hemodialysis is a process of removing waste and excess fluid from blood when kidneys cannot function efficiently. It often involves diverting blood to the filter of the dialysis machin to be cleared of toxic s...
Craniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
Background: Craniospinal irradiation (CSI) of medulloblastoma poses technological challenges due to the involvement of large treatment volume. Commonly, the whole treatment length is covered with two different isocentric...
Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?
MRI workers are occupationally exposed to static and time-varying gradient magnetic fields. While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be a...
Comparison and Evaluation of Different Treatment Plans with IFRT Field and 6 and 18 MV Energies in Hodgkin’s Lymphoma Involvement Neck and Mediastinum
Background: Radiotherapy with large mantle field is an effective technique in increasing the risk of secondary cancers among HL (Hodgkin Lymphoma) patients; therefore, it is essential to choose an effective treatment fie...
Dose Calculation Accuracy of Radiotherapy Treatment Planning Systems in Out-of-Field Regions
NO ABSTRACT