Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach

Journal Title: Journal of Biomedical Physics and Engineering - Year 2019, Vol 9, Issue 3

Abstract

Background: Metal prostheses in patients affect the radiotherapy dose distribution. Metal prostheses with high density and atomic number cause major changes in scattering and attenuation of radiation. The present study aims to assess the impact of metal knee prosthesis with various dimensions and materials on radiotherapy dose distribution. Material and Methods: In this research, the Varian Linac and water phantom were simulated using the MCNPX code. Dose distribution of photon beam in a water phantom, with and without the presence of knee prostheses made of cobalt-chromium-molybdenum alloy, steel, titanium, and titanium alloy used in men and women was investigated using the Monte Carlo simulation. Results: The prosthesis led to an increase in dose in comparison with cases that there was used no prosthesis. According to values of the depth dose percentage, the maximum dose increase was found to be 6.8%, 6.1%, 4%, and 4.29%, and dose reduction 41.18%, 40.66%, 37.76%, and 37.51% for prosthetics with men’s knee dimensions made of cobalt-chromium-molybdenum alloy, steel, titanium alloy, and titanium, respectively. Above all, does increasing to 6.4%, 5.9%, 3.8%, and 3.94% and doses reducing to 40.87%, 40.36%, 36.94%, and 36.69 were observed in prosthetics for women. The highest amount of dose reduction for men’s prostheses made of mentioned materials was found to be 48.75%, 47.7%, 45%, and 45.8%, respectively. In addition, it was 46.36%, 45.8%, 43.8%, and 43.95% for women’s prostheses, respectively. Conclusion: Material will have a significant impact if a part of the knee bone places behind the prosthesis. According to the obtained values, it is recommended to utilize prostheses made of titanium and titanium alloys for knee arthroplasty. The prosthesis can either increase or decrease dose in tumor or lead to increase dose at organs at risk. Citation: Bayatiani M. R, Seif F, Hamidi S, Bagheri S. Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach. J Biomed Phys Eng. 2019;9(3):345-354. https://doi.org/10.31661/jbpe.v0i0.1047.

Authors and Affiliations

F. Seif, M. R. Bayatiani, S. Hamidi

Keywords

Related Articles

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces...

Dosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography

Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free. Objective: The aim of this study was to evaluate the exposure dos...

Comparison and Evaluation of Different Treatment Plans with IFRT Field and 6 and 18 MV Energies in Hodgkin’s Lymphoma Involvement Neck and Mediastinum

Background: Radiotherapy with large mantle field is an effective technique in increasing the risk of secondary cancers among HL (Hodgkin Lymphoma) patients; therefore, it is essential to choose an effective treatment fie...

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI. Objective: In...

In-silico Evaluation of Rare Codons and their Positions in the Structure of ATP8b1 Gene

Background: Progressive familial intrahepatic cholestases (PFIC) are a spectrum of autosomal progressive liver diseases developing to end-stage liver disease. ATP8B1 deficiency caused by mutations in ATP8B1 gene encoding...

Download PDF file
  • EP ID EP613930
  • DOI -
  • Views 84
  • Downloads 0

How To Cite

F. Seif, M. R. Bayatiani, S. Hamidi (2019). Investigating the Impact of Knee Prosthesis in Patients’ Body on Radiation Dose Distribution: A Monte Carlo Approach. Journal of Biomedical Physics and Engineering, 9(3), 345-354. https://europub.co.uk/articles/-A-613930