INVESTIGATION AND CALCULATION OF VALLEYS OF OUTGOING FROM SUBSTATION GROUNDING CONDUCTORS FOR SHORT-CIRCUIT IN SINGLE-PHASE SHORT OF ELECTRICAL GRID

Abstract

Introduction. Earthing device electrical substation in modern conditions must meet both the requirements of electrical safety of people and animals, as well as electromagnetic compatibility requirements established her electrical equipment. These requirements are intended to address issues of protection against surges and interference caused by lightning impulse currents and switching. Aim. To investigate the distribution of single-phase short-circuit current in the substation grounding devices. Task. On the basis of the proposed design scheme of substitution substation grounding device, consisting of a substation earthing system and «cable-supported» an algorithm for calculating the resistance of the grounding device substation and distribution of single-phase short-circuit current on the circuit elements. Method. Mathematical modeling and calculation engine. Results. On the basis of calculations and studies analyzed the current distribution of single-phase short-circuit between the substation earthing system and earthing «rope-reliance». Studies carried out for the actual range of variation of the circuit parameters, showed that the earthing resistance substation substantially affects the current distribution in the one-phase short circuit fault. For example, using the graph shows that with increasing resistance grounding system of "rope-supported" the proportion of single-phase short-circuit current flowing from the substation earthing increases, while the proportion of single-phase short-circuit current flowing from the grounding device supports decreases and vice versa. In addition, when rationing grounding systems at substations for the touch voltage is necessary to analyze all the possible modes of operation of the network, which is substationed. Conclusion. The results obtained are recommended to take into account in the design of grounding systems at substations.

Authors and Affiliations

I. V. Nizhevskyi, V. I. Nizhevskyi, B. Ynoyatov, S. Nasryddyny

Keywords

Related Articles

APPROXIMATE CALCULATION OF BASIC CHARACTERISTICS OF PLASMA AT THE AIR ELECTRIC EXPLOSION OF METAL CONDUCTOR

Purpose. Obtaining approximate calculation correlations for determination of maximal values of temperature Tm, and pressures Pm at a shock wave and speed vm distribution of a shock wave in the plasma products of air elec...

THREE-PHASE ENERGY SUPPLY SYSTEMS SIMULATION FOR THE TOTAL POWER LOSSES COMPONENTS ASSESSMENT

Purpose. The goal is to optimize a structure of Matlab-model of the three-phase energy supply system with power active filter. The mathematical model that describes the energy supply system modes of operation which conta...

MODELING PARAMETERS OF ARC OF ELECTRIC ARC FURNACE

Purpose. The aim is to build a mathematical model of the electric arc of arc furnace (EAF). The model should clearly show the relationship between the main parameters of the arc. These parameters determine the properties...

NON-CANONICAL SPECTRAL DECOMPOSITION OF RANDOM FUNCTIONS OF THE TRACTION VOLTAGE AND CURRENT IN ELECTRIC TRANSPORTATION SYSTEMS

The paper proposes the non-canonical spectral decomposition of random functions of the traction voltages and currents. This decomposition is adapted for the electric transportation systems. The numerical representation i...

DETERMINATION OF ECONOMICALLY JUSTIFIED PARAMETERS OF SYNCHRONOUS DISCONNECTION AT LOW-VOLTAGE CIRCUIT SWITCHING VIA A SYNCHRONOUS VACUUM CONTACTOR

Dependence of a single switching procedure cost upon the contact opening delay time and delay-time spread is derived for a low-voltage synchronous vacuum contactor. For different cost levels, boundaries of permissible va...

Download PDF file
  • EP ID EP301245
  • DOI 10.20998/2074-272X.2015.2.14
  • Views 97
  • Downloads 0

How To Cite

I. V. Nizhevskyi, V. I. Nizhevskyi, B. Ynoyatov, S. Nasryddyny (2015). INVESTIGATION AND CALCULATION OF VALLEYS OF OUTGOING FROM SUBSTATION GROUNDING CONDUCTORS FOR SHORT-CIRCUIT IN SINGLE-PHASE SHORT OF ELECTRICAL GRID. Електротехніка і Електромеханіка, 0(2), 72-75. https://europub.co.uk/articles/-A-301245