Investigation of Transducer Mass Loading Effect in Frequency Response Function (FRF)

Abstract

The accuracy and the reliability of various analyses using the measured FRFs depend strongly on the quality of measured data. It is well known that the quality of measured frequency response functions (FRFs) is adversely affected by many factors, most significant sources being noise and systematic errors like mass loading effects of transducers. A transducer mounted on a vibrating system changes the dynamics of the structure due to the addition of extra mass and introduces errors into measured FRFs. One problem with this is the production of unrealistic results, which cause the measured resonant frequencies to be less than the correct values. These errors also lead to incorrect prediction of modal parameters. In many situations, the mass loading effect is ignored in the analytical and experimental Modelling process, based on a usual assumption that the transducer mass is negligible compared to that of the structure under test. However, when light-weighted structures are investigated, this effect can be significant and it may be necessary to eliminate this undesirable side effect before the measured data are used for further analyses. The mass loading effects of accelerometer and force transducer can be eliminated from measured FRFs (including point FRF and transfer FRF) in shaker modal testing. Considering different sensors for response measurements, two common collocations in shaker modal testing are investigated: (1) shaker + Laser Doppler vibrometer case, in which only force transducer mass loading effects need to be removed, and (2) shaker + accelerometer case, in which both accelerometer and force transducer mass should be eliminated. The Sherman-Morrison identity for the elimination of mass loading effects of accelerometers from measured FRF. The formulation presented can be applied for both fixed transducer (hammer testing) and moving transducer (shaker testing) case. In moving transducer case, a dummy mass is utilized. Also, the transducer mass loading effect on the transfer FRFs can be removed by considering a set of measurements using two accelerometers with different masses. Sometimes, the effect of the extra masses on a measured FRF can be cancelled by cancellation technique for transducers at the driving points. The resonance frequencies of the plate measured with an accelerometer are lower than those of measured without accelerometer. However, after the elimination of the effect of the mass difference between the two accelerometers, both the natural frequencies and the FRFs as a whole are in quite good agreement with the target values.

Authors and Affiliations

A. D. Karle

Keywords

Related Articles

Design and Fabrication of Unified Wheel Opener

Today the life of man is simple and comfortable as various resources are available for each and every process that a person has to perform in his day to day life, and these resources and equipment’s helps the person to p...

Cosmetic Marketing

Pharmaceutical industries today are spending a huge lot of money on marketing. It can be observed that marketing is more commercial with increasing time period. Many strategies are followed in marketing of the pharmaceut...

Islamic Banking: Concept and Future Potential in India

Today that Islamic banking industry showing an average growth rate of 17%-20% annually and comprises around 400 institutions in 75 countries, with an asset under management ranging between US $1.66-2.1 trillion, with exp...

CFD Analysis of Circular Pipe Flat Plate Solar Collector

Solar energy is available in abundance but least used energy source of available renewable energy resources. Solar Energy is being used for some household and commercial purposes like producing steam for commercial usage...

Mental Retardation – Nature, Needs and Identification

izLrqr la”kks/ku i= esa ekufld eanrk & izd`fr] vko”;drk,¡ ,oa igpku ds ckjs esa vuqla/kkudrkZ us dqN izdk”k Mkyk g SA ;qxksa igys Ekkufld eanrk okys O;fDr;ksa dks vekuoh; dgk tkrk FkkA mUgsa tUe ds le; Mqcks dj ekj fn;k...

Download PDF file
  • EP ID EP220488
  • DOI -
  • Views 143
  • Downloads 0

How To Cite

A. D. Karle (2014). Investigation of Transducer Mass Loading Effect in Frequency Response Function (FRF). International journal of Emerging Trends in Science and Technology, 1(4), 584-589. https://europub.co.uk/articles/-A-220488