Laboratory predictors of uphill cycling time trial performance
Journal Title: Journal of Science and Cycling - Year 2014, Vol 3, Issue 2
Abstract
Background: A field test which can be easily integrated into the training routine of cyclists to monitor performance changes is valuable. It has been demonstrated that when performing a 20-min outdoor time trial (TT), cyclists produce approximately 5.4% higher mean power output during uphill than flat routes (Nimmerichter et al., 2012: European Journal of Applied Physiology, 112(1), 69-78). Therefore, this discrepancy raises questions the relationship between uphill TT performance and physiological parameters obtained during laboratory graded exercise tests (GXT), as previously demonstrated on flat courses. Methods: Separated by at least 48 hours, eleven male and one female moderately trained cyclists (30±5 years; 78.7±16.2 kg; 175±8 cm; mean±s) undertook a 30-s Wingate test on a mechanically braked cycle ergometer (Biotec2100, Cefise, Nova Odessa, Brazil) fitted with a power-measuring crank (SRM, Jülich, Germany), a GXT to exhaustion (Computrainer ProLab, RacerMate, Seattle, USA) and a 20-min outdoor uphill TT (2.8% mean gradient). GXT pulmonary gas exchanges were measured using breath-by-breath analyses (K4b2, Cosmed, Rome, Italy). During the TT, power output was measured using a mobile power-meter (PowerTap, Saris, Madison, USA). Results: Multiple linear regressions demonstrated that 95% of the variation in TT mean power output (PTT) was predicted by GXT VO2max and the respiratory compensation point (RCP), with standardized beta coefficients of 0.68 and 0.37 respectively. Moderate intraclass correlation coefficients were demonstrated for 94.6% PTT and RCP power (r = 0.87; 95%CI: 0.47-0.96). Bland Altman plot showed a bias ± random error of 4.4±51.6 W or 1.2±21.1 %. Mean values for Wingate 5-s peak power, Wingate 30-s mean power, PTT and 94.6% PTT were 899±163 W; 668±108 W; 295±53 W and 279±50 W, respectively. Mean values for GXT peak power output (Pmax), VO2max, RCP power and VT power were 341±46 W; 4.44±0.73 L.min-1; 274±45 W and 173±31 W, respectively. Discussion: The results of this study demonstrate that 95% uphill PTT can be explained by physiological laboratory parameters of VO2max and RCP. Moreover, when PTT is adjusted according to the findings of Nimmerichter et al. (2012), RCP power output agrees better with it. Consequently, this finding adds more experimental evidence for the predictive validity of the 20-min outdoor TT to estimate power output at RCP during GXT, provided that the uphill course is taken to account and a 5.4% subtraction is made to PTT. Conclusion: A 20-min outdoor TT performed on an uphill course can be utilized to predict with reasonable accuracy, power output at the respiratory compensation point and to monitor performance changes on moderately trained cyclists.
Authors and Affiliations
AH Bossi| Faculty of Physical Education and Sports, Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil., P Lima| Faculty of Physical Education and Sports, Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil., J Hopker| School of Sport and Exercise Sciences, University of Kent, Chatham Maritime, Chatham, Kent, England., JRP Lima| Faculty of Physical Education and Sports, Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil.
Differences in visual information-seeking behavior between expert and novice time-trial cyclists
Introduction: Pacing can be defined as an ability to distribute available energy resources during the race (Hettinga et al., 2006). It’s a determinant of athletic performance, affected by an interaction between previous...
Spanish cycling and attitudes towards doping of different stakeholders involved
The aim of this study was to know and compare the attitudes towards doping among different groups involved in Spanish cycling: future physical trainers, elite cyclists, young cyclists, and cycling team managers. The samp...
The reliability of a 30-minute performance test on a Lode cycle ergometer
High retest reliability is desirable in tests used to monitor athletic performance. The purpose of the present study was to determine the reliability of a 30-minute cycle test on a cycle ergometer (Lode, Groningen, Nethe...
Comparison of power output demands for a top-10 ranking between Tour de France and Vuelta a España
Background: Grand Tours (GT) are extreme endurance cycling events with about 3500 km covered in twenty-one stages during three weeks. Using the heart rate measurement, Lucia et al. (Lucia et al., 2003: Medicine & Science...
O2score device: analysis of the kinetics of recovery after exercise
The O2Score system was recently developed as a mobile device able to measure the quantity of antioxidants in the body. Since the quantity of antioxidants is modified during effort (to provide a defense system against fre...