LAMELLAR BODY COUNT WITH CELL DYN EMERALD AND CELL DYN RUBY METHODS ON PRETERM BIRTH
Journal Title: Journal of Vocational Health Studies - Year 2017, Vol 1, Issue 1
Abstract
Background: Lamellar bodies are produced by pneumocyte type II cells in the lung alveoli. Lamellar bodies are present in amniotic fluid in increasing quantities as gestation advances, 1 – 5 µm in size, similar in size to small platelets and can be counted on most electronic cell counters in hematology analyzer. Lamellar body count is useful for prediction of fetal lung maturity and neonatal respiratory distress syndrome. The current gold standard for determination of fetal lung maturity is the evaluation of phospholipids in amniotic fluid samples by thin-layer chromatography, but it is time-consuming and not continuously available at most institutions. In this study we compare Cell Dyn Emerald and Cell Dyn Ruby method, which is expected to be a review for lamellar body count method. Purpose: The aim of this study was to analyze lamellar body count with Cell Dyn Emerald and Cell Dyn Ruby method on preterm birth. Methods : This was a cross sectional study. Thirty three samples study were inpatient’s amniotic fluid with premature rupture of membranes in Obstetry and Gynecology ward emergency room Dr. Soetomo Hospital Surabaya. Lamellar body count was counted with Cell Dyn emerald and Cell Dyn Ruby method. The statistical differences were assessed using the ANOVA test . Results : The results showed significant differences (t=49,04), lamellar body count with Cell Dyn Ruby method was much lower than Cell Dyn Emerald method. The lowest result with Cell Dyn Ruby method was 3.38 x 103/µL and 17 x 103/ µL with Cell Dyn Emerald method. The highest results with Cell Dyn Ruby method was 98,2 x 103/ µL and 221 x 103/ µL with Cell Dyn Emerald method. Conclusion : Lamellar body count with impedance method (Cell Dyn Emerald) is significantly higher than optic method (Cell Dyn Ruby).
Authors and Affiliations
Erlinda Widyastuti, Ario Imandri
COMPARATIVE ANALYSIS IMAGE RESULTS OF PANCREAS IN PORTAL VEIN PHASE ON CT SCAN ABDOMEN CONTRAST WITHOUT AND WITH MINIMUM INTENSITY PROJECTION IN CT SCAN 64 SLICE
Background: Minimum Intensity Projection is a post-proccesing technique on CT Scan that useful for showing structures with low Hounsfiled Unit (HU) values such as pancreas. To demonstrate the anatomy and pathology of the...
COMPARISON OF NUMBER OF DIFFUSION GRADIENT DIRECTION IN BRAIN IMAGING DIFFUSION TENSOR; CASE STUDY OF TUMOR BRAIN
Background : Diffusion Tensor Imaging (DTI), namely MRI sequence which is the diffusion of water analysis that shows the complex structure of brain tissue. The weakness of this sequence is scanning time. Number of Diffus...
COMPARISON OF RADIOGRAPHY WRIST JOINT POSTERIOR ANTERIOR (PA) ULNAR DEVIATION CENTRAL RAY VARIATION FOR ASSESSING OS SCAPHOID
Background: The technique of examining the wrist joint to see abnormalities in the carpalia region, especially in the scaphoid os, there is a special technique, namely ulnar deviation with variations of the central ray 1...
STUDY OF SOIL-TRANSMITTED HELMINTHIASIS PREVALENCE IN SCHOOL CHILDREN IN SURABAYA
Background : Soil-Transmitted Helminths infection usually occurs due to poor sanitation in the densely populated area with bad sanitation. It is transmitted by egg present in human feces then contaminate soil. Helminths...
PREVALENCE OF INTESTINAL HELMINTHIASIS IN CHILDREN AT NORTH KEPUTRAN SURABAYA AT 2017
Background: Parasite infection is still an endemic disease that can be found in any place in Indonesia that can cause problems in public health, especially for children. Intestinal helminthiasis can interfere with childr...