Matlab/Simulink Model of High Frequency Converter For Electrosurgical Generators

Abstract

Electrosurgery is a process where high frequency currents are utilized for performing surgical operations like cutting, fulguration, desiccation etc. But due to the change in tissue impedance and slow response of electrosurgical unit to the change in impedance results in output power fluctuation. This leads to charring of tissues. This paper presents a new high frequency converter topology which eliminates these unwanted responses by regulating the power. The simulation is done by using MATLAB/Simulink version 2016a and simulation results are presented.

Authors and Affiliations

Nimitha Gopinath, Praveen Kumar C

Keywords

Related Articles

Analysis and Development of a Reliability Forecasting Model for Injection Substation

This paper is aimed at analyzing and developing a reliability forecasting model for an Injection Substation; a case study of Ugbowo 33/11kV Injection Substation. This project seeks to determine the current reliability st...

Novel Three Phase Five Level Inverter with Reduced Number of Power Electronics Components

Novel three phase five level inverter with reduced number of power electronics components are introduced. This inverter consists of typical three phase two level-bridge inverter with three bidirectional switches and two...

Automated dust detection and cleaning system of PV module

This paper describes the development of an automated dust detection and cleaning system which could be used to clean photovoltaic (PV) modules. Dust accumulation is one of the factors which negatively impact of the PV mo...

Home Automation System And Security System Using GSM

Human life in the present runway is an extremely distressing system. Ordinarily, when we go out, we neglect to keep the house electric machine, gas catch, closed down the screen, home security can't be taken note. Arrang...

Hardware Implementation of Intelligent Controllers for Elementary Luo Converter

Positive output elementary Luo converter performs the conversion from positive DC input voltage to positive DC output voltage. Since Luo converters are non-linear and time-variant systems, the design of high performance...

Download PDF file
  • EP ID EP388720
  • DOI 10.9790/1676-1302032935.
  • Views 201
  • Downloads 0

How To Cite

Nimitha Gopinath, Praveen Kumar C (2018). Matlab/Simulink Model of High Frequency Converter For Electrosurgical Generators. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(2), 29-35. https://europub.co.uk/articles/-A-388720